VOLIUS-OA-MIB :: vlsEdfaInputPower

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsVOLIUS-OA-MIBvlsEdfaInputPower

vlsEdfaInputPower

Module: VOLIUS-OA-MIB

OID (symbolic): VOLIUS-OA-MIB::vlsEdfaInputPower

OID (numeric): 1.3.6.1.4.1.34652.3.7.1.2

Node type: OBJECT-TYPE

Type: VlsDeciDbm

Access: read-only

What is vlsEdfaInputPower?

This is the measured optical input power, in units of 0.1 dBm, on the EDFA input channel identified by vlsEdfaInputIndex, used to confirm the amplifier is receiving a valid signal to boost.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.34652.3.7.1.2
snmpwalk -v2c -c public <target> VOLIUS-OA-MIB::vlsEdfaInputPower

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.34652.3.7.1.2.1
snmpget -v2c -c public <target> VOLIUS-OA-MIB::vlsEdfaInputPower.1

Start monitoring Volius optical network devices with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VOLIUS-OA-MIB::vlsEdfaInputPower OID value, configure state conditions and alerts, and monitor any Volius optical network devices from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.34652voliusVOLIUS-OA-MIB
1.3.6.1.4.1.34652.3vlsEdfaVOLIUS-OA-MIB
1.3.6.1.4.1.34652.3.7vlsEdfaInputTableVOLIUS-OA-MIB
1.3.6.1.4.1.34652.3.7.1vlsEdfaInputEntryVOLIUS-OA-MIB
1.3.6.1.4.1.34652.3.7.1.2vlsEdfaInputPowerVOLIUS-OA-MIB