All MIBs › VISINET2-MIB › uemSensorValue
uemSensorValue
Module: VISINET2-MIB
OID (symbolic): VISINET2-MIB::uemSensorValue
OID (numeric): 1.3.6.1.4.1.223.10.6.17.1.6
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The current numeric value of the sensor. The interpretation of this value is related to the type of sensor. Fan sensor values are reported in rpms (revolutions per minute). Voltage sensor values are reported in millivolts. A value of 3300 means 3.3 volts. Temperature sensor values are reported as hundreths of Celsius degrees. A value of 2500 means 25.0 degrees.
What is uemSensorValue?
The current numeric reading of the sensor, whose unit depends on uemSensorType: RPM for fans, millivolts for voltage (3300 = 3.3V), and hundredths of a degree Celsius for temperature (2500 = 25.0C). Admins graph this over time per sensor to watch for a fan slowly failing or a voltage rail drifting.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.223.10.6.17.1.6 snmpwalk -v2c -c public <target> VISINET2-MIB::uemSensorValue
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.223.10.6.17.1.6.1 snmpget -v2c -c public <target> VISINET2-MIB::uemSensorValue.1
Start monitoring ViSiNet2 video surveillance/security appliance (agent/BIOS firmware-version inventory status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VISINET2-MIB::uemSensorValue OID value, configure state conditions and alerts, and monitor any ViSiNet2 video surveillance/security appliance (agent/BIOS firmware-version inventory status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.223 | unisys | SMSAGENT-MIB |
| 1.3.6.1.4.1.223.10 | unisysOpen | SMSAGENT-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.223.10.6 | unisysEnvMonitor | VISINET2-MIB |
| 1.3.6.1.4.1.223.10.6.17 | uemSensorTable | VISINET2-MIB |
| 1.3.6.1.4.1.223.10.6.17.1 | uemSensorTableEntry | VISINET2-MIB |
| 1.3.6.1.4.1.223.10.6.17.1.6 | uemSensorValue | VISINET2-MIB |