All MIBs › VDSL-LINE-MIB › vdslChan1DayIntervalFixedOctets
vdslChan1DayIntervalFixedOctets
Module: VDSL-LINE-MIB
OID (symbolic): VDSL-LINE-MIB::vdslChan1DayIntervalFixedOctets
OID (numeric): 1.3.6.1.2.1.10.97.1.1.9.1.3
Node type: OBJECT-TYPE
Type: HCPerfCurrentCount
Access: read-only
Description: Count of corrected octets in this interval.
What is vdslChan1DayIntervalFixedOctets?
This counter measures the number of octets (bytes) corrected by error-correction on a VDSL line in the current 24-hour interval. High values indicate the line is experiencing interference or signal quality degradation. A tech uses this to diagnose why a customer's DSL is getting slow before line quality drops further.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.97.1.1.9.1.3 snmpwalk -v2c -c public <target> VDSL-LINE-MIB::vdslChan1DayIntervalFixedOctets
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.2.1.10.97.1.1.9.1.3.1 snmpget -v2c -c public <target> VDSL-LINE-MIB::vdslChan1DayIntervalFixedOctets.1
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> vdslChan1DayIntervalFixedOctets.1
Start monitoring vendor-neutral, standards-based MIB, DSLAMs and VDSL modems/transceivers (line coding/profile/transceiver-inventory status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the VDSL-LINE-MIB::vdslChan1DayIntervalFixedOctets OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB, DSLAMs and VDSL modems/transceivers (line coding/profile/transceiver-inventory status) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.2 | mgmt | AXON-MIB |
| 1.3.6.1.2.1 | mib_2 | AXON-MIB |
| 1.3.6.1.2.1.10 | transmission | CHECKPOINT-MIB-2 |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.2.1.10.97 | vdslMIB | VDSL-LINE-MIB |
| 1.3.6.1.2.1.10.97.1 | vdslLineMib | VDSL-LINE-MIB |
| 1.3.6.1.2.1.10.97.1.1 | vdslMibObjects | VDSL-LINE-MIB |
| 1.3.6.1.2.1.10.97.1.1.9 | vdslChan1DayIntervalTable | VDSL-LINE-MIB |
| 1.3.6.1.2.1.10.97.1.1.9.1 | vdslChan1DayIntervalEntry | VDSL-LINE-MIB |
| 1.3.6.1.2.1.10.97.1.1.9.1.3 | vdslChan1DayIntervalFixedOctets | VDSL-LINE-MIB |