usdERXSysAdminTimingSource

Module: Unisphere-Data-ERX-System-MIB

OID (symbolic): Unisphere-Data-ERX-System-MIB::usdERXSysAdminTimingSource

OID (numeric): 1.3.6.1.4.1.4874.2.2.17.1.1.16

Node type: OBJECT-TYPE

Type: UsdTimingSelector

Access: read-write

Description: The administrative timing source for the ERX system. The ERX periodically monitors the status of three timing sources, primary, secondary and tertiary. If the systems current timing source fails, the system will automatically downgrade to the next timing source. If the system is configured to automatically upgrade (usdERXSysTimingDisableAutoUpgrade is set to false(2)) the system will switch back to the higher timing source when it becomes available.

A timing source failure can be detected by comparing the operational and admin timing sources. If they are not equal, the system has swapped timing sources because the administratively set value is in the error state.

What is usdERXSysAdminTimingSource?

Sets the administratively selected timing source (primary, secondary, or tertiary) for the ERX system's clock; the system automatically downgrades to the next source if the current one fails and, if auto-upgrade is enabled, switches back up when a higher source recovers. Admins compare this against usdERXSysOperTimingSource -- a mismatch means the system has already failed over due to a timing source problem.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.17.1.1.16
snmpwalk -v2c -c public <target> Unisphere-Data-ERX-System-MIB::usdERXSysAdminTimingSource

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.4874.2.2.17.1.1.16.1
snmpget -v2c -c public <target> Unisphere-Data-ERX-System-MIB::usdERXSysAdminTimingSource.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.4874.2.2.17.1.1.16.1 s <value>

Start monitoring Juniper/Unisphere ERX Edge Router (chassis hardware-revision/software-version/redundancy status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the Unisphere-Data-ERX-System-MIB::usdERXSysAdminTimingSource OID value, configure state conditions and alerts, and monitor any Juniper/Unisphere ERX Edge Router (chassis hardware-revision/software-version/redundancy status) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.4874juniperUniJuniper-UNI-SMI
1.3.6.1.4.1.4874.2juniperUniMibsJuniper-UNI-SMI
1.3.6.1.4.1.4874.2.2juniMibsJuniper-MIBs
1.3.6.1.4.1.4874.2.2.17juniERXSysMIBJuniper-ERX-System-MIB
1.3.6.1.4.1.4874.2.2.17.1juniERXSysObjectsJuniper-ERX-System-MIB
1.3.6.1.4.1.4874.2.2.17.1.1juniERXSysGeneralJuniper-ERX-System-MIB
Numeric OIDNameModule
1.3.6.1.4.1.4874.2.2.17.1.1.16usdERXSysAdminTimingSourceUnisphere-Data-ERX-System-MIB