USHA-MIB :: upsTestBatteryTestElapsedTime

MIB Reference — IPNetwork Monitor

All MIBsUSHA-MIBupsTestBatteryTestElapsedTime

upsTestBatteryTestElapsedTime

Module: USHA-MIB

OID (symbolic): USHA-MIB::upsTestBatteryTestElapsedTime

OID (numeric): 1.3.6.1.4.1.2468.1.2.1.1.6.5

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description:

The amount of time, in TimeTicks, since the test in progress was initiated, or, if no test is in progress, the previous test took to complete. If the value of upsTestResultsSummary is noTestsInitiated(6), upsTestElapsedTime has the value 00:00:00.00.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2468.1.2.1.1.6.5
snmpwalk -v2c -c public <target> USHA-MIB::upsTestBatteryTestElapsedTime

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2468.1.2.1.1.6.5.1
snmpget -v2c -c public <target> USHA-MIB::upsTestBatteryTestElapsedTime.1

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.2468ingrasysUSHA-MIB
1.3.6.1.4.1.2468.1productUSHA-MIB
1.3.6.1.4.1.2468.1.2upsAgentUSHA-MIB
1.3.6.1.4.1.2468.1.2.1ushapUSHA-MIB
1.3.6.1.4.1.2468.1.2.1.1upsObjectGroupUSHA-MIB
1.3.6.1.4.1.2468.1.2.1.1.6upsTestGroupUSHA-MIB
1.3.6.1.4.1.2468.1.2.1.1.6.5upsTestBatteryTestElapsedTimeUSHA-MIB