USHA-MIB :: upsControlDelay

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsUSHA-MIBupsControlDelay

upsControlDelay

Module: USHA-MIB

OID (symbolic): USHA-MIB::upsControlDelay

OID (numeric): 1.3.6.1.4.1.2468.1.2.1.1.7.4.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The Delay after the occurance of the curresponding shutdown event that USHA should issue shutdown request to connected clients. For WeeklyScheduledShutdown and SpecialScheduledShutdown, this is the time before the configured Shutdowntime when USHA will start sending the warning message to the connected clients. The value is in units of minutes.

What is upsControlDelay?

The delay, in minutes, after the triggering shutdown event occurs before USHA sends the shutdown request to connected clients; for weekly/special-day schedules this is instead how far ahead of the scheduled time warning messages begin.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2468.1.2.1.1.7.4.1.3
snmpwalk -v2c -c public <target> USHA-MIB::upsControlDelay

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2468.1.2.1.1.7.4.1.3.1
snmpget -v2c -c public <target> USHA-MIB::upsControlDelay.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2468.1.2.1.1.7.4.1.3.1 i <value>

Start monitoring Ingrasys / USHA-branded Uninterruptible Power Supply (UPS) units (battery health/power-state trap status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the USHA-MIB::upsControlDelay OID value, configure state conditions and alerts, and monitor any Ingrasys / USHA-branded Uninterruptible Power Supply (UPS) units (battery health/power-state trap status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2468ingrasysUSHA-MIB
1.3.6.1.4.1.2468.1productUSHA-MIB
1.3.6.1.4.1.2468.1.2upsAgentUSHA-MIB
1.3.6.1.4.1.2468.1.2.1ushapUSHA-MIB
1.3.6.1.4.1.2468.1.2.1.1upsObjectGroupUSHA-MIB
1.3.6.1.4.1.2468.1.2.1.1.7upsControlGroupUSHA-MIB
1.3.6.1.4.1.2468.1.2.1.1.7.4upsControlShutdownParametersTableUSHA-MIB
1.3.6.1.4.1.2468.1.2.1.1.7.4.1upsControlShutdownParametersEntryUSHA-MIB
1.3.6.1.4.1.2468.1.2.1.1.7.4.1.3upsControlDelayUSHA-MIB