All MIBs › UMC1000-MIB › umc1LoopDiagnosticsResponseStartToneIdentifier
umc1LoopDiagnosticsResponseStartToneIdentifier
Module: UMC1000-MIB
OID (symbolic): UMC1000-MIB::umc1LoopDiagnosticsResponseStartToneIdentifier
OID (numeric): 1.3.6.1.4.1.2067.1.1.2.18.2.1.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Enumerated value from SIS: 0x01 = Loop Characteristics 0x02 = CCF for Tones 0 to 42 0x03 = CCF for Tones 43 to 85 0x04 = CCF for Tones 86 to 128 0x05 = CCF for Tones 129 to 171 0x06 = CCF for Tones 172 to 214 0x07 = CCF for Tones 215 to 255 0x08 = CCF for Tones 256 to 298 0x09 = CCF for Tones 299 to 341 0x0A = CCF for Tones 342 to 384 0x0B = CCF for Tones 385 to 427 0x0C = CCF for Tones 428 to 470 0x0D = CCF for Tones 471 to 511 0x0E = QLN for Tones 0 to 42 0x0F = QLN for Tones 43 to 85 0x10 = QLN for Tones 86 to 128 0x11 = QLN for Tones 129 to 171 0x12 = QLN for Tones 172 to 214 0x13 = QLN for Tones 215 to 255 0x14 = QLN for Tones 256 to 298 0x15 = QLN for Tones 299 to 341 0x16 = QLN for Tones 342 to 384 0x17 = QLN for Tones 385 to 427 0x18 = QLN for Tones 428 to 470 0x19 = QLN for Tones 471 to 511 0x1A = SNR for Tones 0 to 42 0x1B = SNR for Tones 43 to 85 0x1C = SNR for Tones 86 to 128 0x1D = SNR for Tones 129 to 171 0x1E = SNR for Tones 172 to 214 0x1F = SNR for Tones 215 to 255 0x20 = SNR for Tones 256 to 298 0x21 = SNR for Tones 299 to 341 0x22 = SNR for Tones 342 to 384 0x23 = SNR for Tones 385 to 427 0x24 = SNR for Tones 428 to 470 0x25 = SNR for Tones 471 to 511
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2067.1.1.2.18.2.1.3 snmpwalk -v2c -c public <target> UMC1000-MIB::umc1LoopDiagnosticsResponseStartToneIdentifier
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.2067.1.1.2.18.2.1.3.1 snmpget -v2c -c public <target> UMC1000-MIB::umc1LoopDiagnosticsResponseStartToneIdentifier.1
Start monitoring UMC1000 universal media converter chassis (per-shelf/slot facility alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UMC1000-MIB::umc1LoopDiagnosticsResponseStartToneIdentifier OID value, configure state conditions and alerts, and monitor any UMC1000 universal media converter chassis (per-shelf/slot facility alarm status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.2067.1.1.2.18 | umc1LoopDiagnostics | UMC1000-MIB |
| 1.3.6.1.4.1.2067.1.1.2.18.2 | umc1LoopDiagnosticsResponseTable | UMC1000-MIB |
| 1.3.6.1.4.1.2067.1.1.2.18.2.1 | umc1LoopDiagnosticsResponseEntry | UMC1000-MIB |
| 1.3.6.1.4.1.2067.1.1.2.18.2.1.3 | umc1LoopDiagnosticsResponseStartToneIdentifier | UMC1000-MIB |