UMC1000-MIB :: umc1AtmProtGrpData

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsUMC1000-MIBumc1AtmProtGrpData

umc1AtmProtGrpData

Module: UMC1000-MIB

OID (symbolic): UMC1000-MIB::umc1AtmProtGrpData

OID (numeric): 1.3.6.1.4.1.2067.1.1.2.1.11.1.2

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-write

Description: The ATM Protection Group Provisioning record. For the initial implementation the OCTET representation will be as follows : octet[0] Version number of the octet representation being used to define the following provisioning data. The version number for the initial implementation will be 0x01.

For Version number 0x01 the remaining octets will be defined as follows :

octet[1] DB specifier octet octet[2] - [n] Octet packed ATM Protection Group Provisioning record.

In a GET Request the data field is empty. In a SET Request it contains the ATM Protection provisioning record to be written to the UMC database.

In order to delete a ATM Protection Group, the Management Station *MUST* : 1. perform a SET operation and send an octet string of length 2 octet (for the version octet) with octet[0] set to a valid version number, octet[1] set to a valid DB type specifier and with NO additional data octets supplied. OR 2. perform a SET operation with octet[0] set to a valid version number, octet[1] set to a valid DB type specifier and with all following octets of umc1AtmProtGrpData set to the values of a DEFAULT ATM Protection Group provisioning record.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.2067.1.1.2.1.11.1.2
snmpwalk -v2c -c public <target> UMC1000-MIB::umc1AtmProtGrpData

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.2067.1.1.2.1.11.1.2.1
snmpget -v2c -c public <target> UMC1000-MIB::umc1AtmProtGrpData.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.2067.1.1.2.1.11.1.2.1 s <value>

Start monitoring UMC1000 universal media converter chassis (per-shelf/slot facility alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UMC1000-MIB::umc1AtmProtGrpData OID value, configure state conditions and alerts, and monitor any UMC1000 universal media converter chassis (per-shelf/slot facility alarm status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.2067.1.1.2.1umc1SystemUMC1000-MIB
1.3.6.1.4.1.2067.1.1.2.1.11umc1AtmProtGrpTableUMC1000-MIB
1.3.6.1.4.1.2067.1.1.2.1.11.1umc1AtmProtGrpEntryUMC1000-MIB
1.3.6.1.4.1.2067.1.1.2.1.11.1.2umc1AtmProtGrpDataUMC1000-MIB