Module: UBQS-REDUNDANCY-MIB

OID (symbolic): UBQS-REDUNDANCY-MIB::ubiPeerCpuOneMin

OID (numeric): 1.3.6.1.4.1.7800.100.29.2.2.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: CPU busy percentage in the last 1 minute period.

What is ubiPeerCpuOneMin?

The peer appliance's CPU busy percentage averaged over the last 1 minute. Monitoring this alongside the local unit's own CPU load lets an admin confirm the standby has adequate headroom to take over if a failover occurs.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.7800.100.29.2.2.2
snmpwalk -v2c -c public <target> UBQS-REDUNDANCY-MIB::ubiPeerCpuOneMin

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.7800.100.29.2.2.2.1
snmpget -v2c -c public <target> UBQS-REDUNDANCY-MIB::ubiPeerCpuOneMin.1

Start monitoring Ubiquoss switches, access network appliances deployed in redundant pairs (active/standby role and failover status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the UBQS-REDUNDANCY-MIB::ubiPeerCpuOneMin OID value, configure state conditions and alerts, and monitor any Ubiquoss switches, access network appliances deployed in redundant pairs (active/standby role and failover status) from a single console.

How to Use in IPNetwork Monitor

Select a Ubiquoss switch or access-network appliance deployed in a redundant pair (active/standby role and failover status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type ubiPeerCpuOneMin into the Find box to locate it in the OID tree, then select it and click OK. It reports cPU busy percentage in the last 1 minute period. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if utilization exceeds 85%, a common warning threshold before sustained high load affects performance. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.7800ubiquossUBIQUOSS-SMI
1.3.6.1.4.1.7800.100ubiMgmtv2UBQS-SMI
Numeric OIDNameModule
1.3.6.1.4.1.7800.100.29ubiRedundancyMIBUBQS-REDUNDANCY-MIB
1.3.6.1.4.1.7800.100.29.2ubiRedundancyPeerObjectsUBQS-REDUNDANCY-MIB
1.3.6.1.4.1.7800.100.29.2.2ubiPeerResourceUBQS-REDUNDANCY-MIB
1.3.6.1.4.1.7800.100.29.2.2.2ubiPeerCpuOneMinUBQS-REDUNDANCY-MIB