TRANGOP5830S-MU-MIB :: muismRxThreshold

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsTRANGOP5830S-MU-MIBmuismRxThreshold

muismRxThreshold

Module: TRANGOP5830S-MU-MIB

OID (symbolic): TRANGOP5830S-MU-MIB::muismRxThreshold

OID (numeric): 1.3.6.1.4.1.5454.1.22.2.5.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: ISM RF rx threshold (in dBm). It specifies the receiver sensitivity of the master. By default, the radio's sensitivity is -82dBm. The higher the threshold is, the less sensitive the radio will be. In M5800S, the value -90 represents the rfrxthreshold is disabled.

What is muismRxThreshold?

Sets the ISM-band receiver sensitivity threshold in dBm; a higher (less negative) value makes the radio less sensitive, while -90 disables the threshold entirely on the M5800S. An admin raises this threshold in a noisy RF environment to reject weak interfering signals, at the cost of also rejecting a genuinely weak but wanted signal.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5454.1.22.2.5.4
snmpwalk -v2c -c public <target> TRANGOP5830S-MU-MIB::muismRxThreshold

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5454.1.22.2.5.4.1
snmpget -v2c -c public <target> TRANGOP5830S-MU-MIB::muismRxThreshold.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5454.1.22.2.5.4.1 i <value>

Start monitoring Trango P5830S wireless master unit radio (subscriber-unit registration/link status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TRANGOP5830S-MU-MIB::muismRxThreshold OID value, configure state conditions and alerts, and monitor any Trango P5830S wireless master unit radio (subscriber-unit registration/link status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5454trangoTRANGO-APEX-MIB
1.3.6.1.4.1.5454.1tbwTRANGO-APEX-MIB
Numeric OIDNameModule
1.3.6.1.4.1.5454.1.22p5830smuTRANGOP5830S-MU-MIB
1.3.6.1.4.1.5454.1.22.2murfTRANGOP5830S-MU-MIB
1.3.6.1.4.1.5454.1.22.2.5muismTRANGOP5830S-MU-MIB
1.3.6.1.4.1.5454.1.22.2.5.4muismRxThresholdTRANGOP5830S-MU-MIB