dot5StatsLineErrors

Module: TOKENRING-MIB

OID (symbolic): TOKENRING-MIB::dot5StatsLineErrors

OID (numeric): 1.3.6.1.2.1.10.9.2.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This counter is incremented when a frame or token is copied or repeated by a station, the E bit is zero in the frame or token and one of the following conditions exists: 1) there is a non-data bit (J or K bit) between the SD and the ED of the frame or token, or 2) there is an FCS error in the frame.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.10.9.2.1.2
snmpwalk -v2c -c public <target> TOKENRING-MIB::dot5StatsLineErrors

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.10.9.2.1.2.1
snmpget -v2c -c public <target> TOKENRING-MIB::dot5StatsLineErrors.1

Start monitoring Network devices with IEEE Token Ring (802.5) interfaces (ring status/soft-error statistics) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TOKENRING-MIB::dot5StatsLineErrors OID value, configure state conditions and alerts, and monitor any Network devices with IEEE Token Ring (802.5) interfaces (ring status/soft-error statistics) from a single console.

How to Use in IPNetwork Monitor

Select a Network devices with IEEE Token Ring (802.5) interface (ring status/soft-error statistics) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type dot5StatsLineErrors into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports a count of Token Ring line errors — frames or tokens copied/repeated with a zero E bit and a non-data or invalid framing condition. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (10 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAPERTUS-NPG-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.10transmissionCHECKPOINT-MIB-2
1.3.6.1.2.1.10.9dot5RFC1231-MIB
1.3.6.1.2.1.10.9.2dot5StatsTableRFC1231-MIB
1.3.6.1.2.1.10.9.2.1dot5StatsEntryRFC1231-MIB
Numeric OIDNameModule
1.3.6.1.2.1.10.9.2.1.2dot5StatsLineErrorsTOKENRING-MIB