TN-NAS-MIB :: tnNASRadiusAssignedVlanEnabled

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › TN-NAS-MIB › tnNASRadiusAssignedVlanEnabled

tnNASRadiusAssignedVlanEnabled

Module: TN-NAS-MIB

OID (symbolic): TN-NAS-MIB::tnNASRadiusAssignedVlanEnabled

OID (numeric): 1.3.6.1.4.1.868.2.5.125.1.2.1.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When RADIUS-Assigned VLAN is both globally enabled and enabled (checked) for a given port, the switch reacts to VLAN ID information carried in the RADIUS Access-Accept packet transmitted by the RADIUS server when a supplicant is successfully authenticated. If present and valid, the port's Port VLAN ID will be changed to this VLAN ID, the port will be set to be a member of that VLAN ID, and the port will be forced into VLAN unaware mode. Once assigned, all traffic arriving on the port will be classified and switched on the RADIUS-assigned VLAN ID. If (re-)authentication fails or the RADIUS Access-Accept packet no longer carries a VLAN ID or it's invalid, or the supplicant is otherwise no longer present on the port, the port's VLAN ID is immediately reverted to the original VLAN ID (which may be changed by the administrator in the meanwhile without affecting the RADIUS-assigned). This option is only available for single-client modes, i.e. Port-based 802.1X, Single 802.1X.

What is tnNASRadiusAssignedVlanEnabled?

Enables or disables RADIUS-assigned VLAN on this specific port (in addition to the global setting); when active, a successfully authenticated supplicant's RADIUS Access-Accept can move this port's VLAN membership until the client is no longer authenticated. Only available in single-client modes (Port-based 802.1X, Single 802.1X).

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.868.2.5.125.1.2.1.1.4
snmpwalk -v2c -c public <target> TN-NAS-MIB::tnNASRadiusAssignedVlanEnabled

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.868.2.5.125.1.2.1.1.4.1
snmpget -v2c -c public <target> TN-NAS-MIB::tnNASRadiusAssignedVlanEnabled.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.868.2.5.125.1.2.1.1.4.1 i <value>

Start monitoring Transition Networks managed switch with 802.1X port authentication (re-auth/guest-VLAN status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TN-NAS-MIB::tnNASRadiusAssignedVlanEnabled OID value, configure state conditions and alerts, and monitor any Transition Networks managed switch with 802.1X port authentication (re-auth/guest-VLAN status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.868transitionTRANSITION-SMI
1.3.6.1.4.1.868.2productsTRANSITION-SMI
1.3.6.1.4.1.868.2.5tnProductsTRANSITION-SMI
Numeric OIDNameModule
1.3.6.1.4.1.868.2.5.125tnNASMIBTN-NAS-MIB
1.3.6.1.4.1.868.2.5.125.1tnNASMIBObjectsTN-NAS-MIB
1.3.6.1.4.1.868.2.5.125.1.2tnNASPortMgmtTN-NAS-MIB
1.3.6.1.4.1.868.2.5.125.1.2.1tnNASPortCfgTableTN-NAS-MIB
1.3.6.1.4.1.868.2.5.125.1.2.1.1tnNASPortCfgEntryTN-NAS-MIB
1.3.6.1.4.1.868.2.5.125.1.2.1.1.4tnNASRadiusAssignedVlanEnabledTN-NAS-MIB