TN-MGMT-MIB :: tnDevSysHwInforCPUtmp

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsTN-MGMT-MIBtnDevSysHwInforCPUtmp

tnDevSysHwInforCPUtmp

Module: TN-MGMT-MIB

OID (symbolic): TN-MGMT-MIB::tnDevSysHwInforCPUtmp

OID (numeric): 1.3.6.1.4.1.868.2.5.3.1.1.1.2.1.5

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicates the temperature of CPU.

What is tnDevSysHwInforCPUtmp?

This OID holds a numerical temperature reading in degrees (Celsius or Fahrenheit depending on the device) of the CPU core. Monitoring this value lets you track heat buildup and predict overheating before the CPU throttles performance or shuts down. A network operator would watch this during heavy loads or in warm datacenters to ensure cooling is adequate and avoid unexpected outages.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.868.2.5.3.1.1.1.2.1.5
snmpwalk -v2c -c public <target> TN-MGMT-MIB::tnDevSysHwInforCPUtmp

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.868.2.5.3.1.1.1.2.1.5.1
snmpget -v2c -c public <target> TN-MGMT-MIB::tnDevSysHwInforCPUtmp.1

Start monitoring Transition Networks media conversion/networking products, entire product line (device naming/uptime/reset status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TN-MGMT-MIB::tnDevSysHwInforCPUtmp OID value, configure state conditions and alerts, and monitor any Transition Networks media conversion/networking products, entire product line (device naming/uptime/reset status) from a single console.

How to Use in IPNetwork Monitor

Select a Transition Networks media-conversion or networking product as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type tnDevSysHwInforCPUtmp into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. It reports the device's current CPU temperature. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the reported value exceeds the level expected for healthy operation, since sustained high CPU temperature often precedes thermal throttling or hardware degradation. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.868transitionTRANSITION-SMI
1.3.6.1.4.1.868.2productsTRANSITION-SMI
1.3.6.1.4.1.868.2.5tnProductsTRANSITION-SMI
Numeric OIDNameModule
1.3.6.1.4.1.868.2.5.3tnMgmtMIBTN-MGMT-MIB
1.3.6.1.4.1.868.2.5.3.1tnMgmtObjectsTN-MGMT-MIB
1.3.6.1.4.1.868.2.5.3.1.1tnDevMgmtTN-MGMT-MIB
1.3.6.1.4.1.868.2.5.3.1.1.1tnDevSysMgmtTN-MGMT-MIB
1.3.6.1.4.1.868.2.5.3.1.1.1.2tnDevSysHwInforTableTN-MGMT-MIB
1.3.6.1.4.1.868.2.5.3.1.1.1.2.1tnDevSysHwInforEntryTN-MGMT-MIB
1.3.6.1.4.1.868.2.5.3.1.1.1.2.1.5tnDevSysHwInforCPUtmpTN-MGMT-MIB