TMU-MIB :: fibTmuPortsGenCloseRun

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TMU-MIB › fibTmuPortsGenCloseRun

fibTmuPortsGenCloseRun

Module: TMU-MIB

OID (symbolic): TMU-MIB::fibTmuPortsGenCloseRun

OID (numeric): 1.3.6.1.4.1.22.60.5.30.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When setting this object to the value of close (2) the indicated port on Tau will be closed, the related led will start blinking at a slow rate and port will not be opened before it is set to the value of open (1). Setting to the value of open (1) does not guarantee the opening of the indicated Tau port but will only allow the Tmu system to let this port into the ring if it obeys the rules of token ring. Reading this object returns the value last set by the manager (or the default value). This command holds only until the next system reset. To make sure it remains valid after reset, use 'fibTmuPortsGenClosePerm'. This command only affects ports on Tau. If there is no Tau attached when command is issued, then it is stored in memory and goes into effect when a Tau is attached. This command will have no effect of a station directly attached to the Tmu. To detach a directly attached station, use 'fibTmuPortsManagerCloseRun' (See above).

What is fibTmuPortsGenCloseRun?

Setting this to close(2) closes the indicated port on the attached Tau immediately, blinks its LED slowly, and keeps it closed until set back to open(1); open(1) only allows (doesn't guarantee) re-entry to the ring if the port follows token ring rules. Reading it returns the manager's last-set value or the default. Admins use it to manually shut a specific downstream port on a Tau, mirroring fibTmuPortsManagerCloseRun but scoped to a Tau-level port rather than a Tmu-level one.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22.60.5.30.1.4
snmpwalk -v2c -c public <target> TMU-MIB::fibTmuPortsGenCloseRun

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22.60.5.30.1.4.1
snmpget -v2c -c public <target> TMU-MIB::fibTmuPortsGenCloseRun.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.22.60.5.30.1.4.1 i <value>

Start monitoring Legacy networking equipment, enterprise OID 22 fibronics (firmware inventory/fault-handling status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TMU-MIB::fibTmuPortsGenCloseRun OID value, configure state conditions and alerts, and monitor any Legacy networking equipment, enterprise OID 22 fibronics (firmware inventory/fault-handling status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22spartacusCMU-MIB
Numeric OIDNameModule
1.3.6.1.4.1.22.60tmuTMU-MIB
1.3.6.1.4.1.22.60.5tmuPortsTMU-MIB
1.3.6.1.4.1.22.60.5.30fibTmuPortsAllTableTMU-MIB
1.3.6.1.4.1.22.60.5.30.1fibTmuPortsAllEntryTMU-MIB
1.3.6.1.4.1.22.60.5.30.1.4fibTmuPortsGenCloseRunTMU-MIB