TMU-MIB :: fibTmuFunctOk2BeaconRun

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TMU-MIB › fibTmuFunctOk2BeaconRun

fibTmuFunctOk2BeaconRun

Module: TMU-MIB

OID (symbolic): TMU-MIB::fibTmuFunctOk2BeaconRun

OID (numeric): 1.3.6.1.4.1.22.60.8.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The upper bound for time period starting at the insertion of a problem till ring status indicates beaconing. In units of milliseconds. Minimal value: 1100. maximal value 2500. Factory default: 2000. To change this object, load 'fibTmuFunctOk2BeaconPerm' into non-volatile ram. The value written into non volatile memory is loaded into the current value only after reset.

What is fibTmuFunctOk2BeaconRun?

This is the run-time (currently effective) value of the upper bound on the time period from the insertion of a problem until ring status indicates beaconing. Valid range is 1100 to 2500 (milliseconds); factory default is 2000. This is a read-only snapshot of what's actually in effect right now -- to change it, an admin must set fibTmuFunctOk2BeaconPerm and then reset the system, since the new value only takes effect in this Run object after a reset. Admins tune this to control how long the system allows before it expects a newly-inserted fault to manifest as beaconing.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22.60.8.1.3
snmpwalk -v2c -c public <target> TMU-MIB::fibTmuFunctOk2BeaconRun

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22.60.8.1.3.1
snmpget -v2c -c public <target> TMU-MIB::fibTmuFunctOk2BeaconRun.1

Start monitoring Legacy networking equipment, enterprise OID 22 fibronics (firmware inventory/fault-handling status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TMU-MIB::fibTmuFunctOk2BeaconRun OID value, configure state conditions and alerts, and monitor any Legacy networking equipment, enterprise OID 22 fibronics (firmware inventory/fault-handling status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22spartacusCMU-MIB
Numeric OIDNameModule
1.3.6.1.4.1.22.60tmuTMU-MIB
1.3.6.1.4.1.22.60.8tmuFunctionTMU-MIB
1.3.6.1.4.1.22.60.8.1fibTmuFunctRtpGrpVrsRunTMU-MIB
1.3.6.1.4.1.22.60.8.1.3fibTmuFunctOk2BeaconRunTMU-MIB