TMU-MIB :: fibTmuFunctLinkPtifPerm

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TMU-MIB › fibTmuFunctLinkPtifPerm

fibTmuFunctLinkPtifPerm

Module: TMU-MIB

OID (symbolic): TMU-MIB::fibTmuFunctLinkPtifPerm

OID (numeric): 1.3.6.1.4.1.22.60.8.2.10

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When problem in TMU segment is discovered then if this flag is TRUE, first of all try to find problem between last inserted stations. Values: 1 - FALSE, 2 - TRUE. Factory default: TRUE. Setting this variable loads it into non volatile memory. The value written into non volatile memory is loaded into the current value only after reset.

What is fibTmuFunctLinkPtifPerm?

This sets, in non-volatile memory, whether, when a problem in the Tmu segment is discovered, the system should first try to find the problem between the most recently inserted stations. Valid range is a boolean (FALSE/TRUE); factory default is TRUE. Setting this object stores the new value for the next reset, but does not change the currently-effective fibTmuFunctLinkPtifRun value until the system is actually reset. Admins leave this enabled so recovery first suspects a just-inserted station, which is often the actual cause of a newly-detected fault, then schedule a reset to apply the change.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22.60.8.2.10
snmpwalk -v2c -c public <target> TMU-MIB::fibTmuFunctLinkPtifPerm

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22.60.8.2.10.1
snmpget -v2c -c public <target> TMU-MIB::fibTmuFunctLinkPtifPerm.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.22.60.8.2.10.1 i <value>

Start monitoring Legacy networking equipment, enterprise OID 22 fibronics (firmware inventory/fault-handling status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TMU-MIB::fibTmuFunctLinkPtifPerm OID value, configure state conditions and alerts, and monitor any Legacy networking equipment, enterprise OID 22 fibronics (firmware inventory/fault-handling status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22spartacusCMU-MIB
Numeric OIDNameModule
1.3.6.1.4.1.22.60tmuTMU-MIB
1.3.6.1.4.1.22.60.8tmuFunctionTMU-MIB
1.3.6.1.4.1.22.60.8.2fibTmuFunctRtpGrpVrsPermTMU-MIB