TMU-MIB :: fibTmuFunctCheckAogTauRun

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › TMU-MIB › fibTmuFunctCheckAogTauRun

fibTmuFunctCheckAogTauRun

Module: TMU-MIB

OID (symbolic): TMU-MIB::fibTmuFunctCheckAogTauRun

OID (numeric): 1.3.6.1.4.1.22.60.8.1.8

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Flag is used during BRUTAL recovery (single problem). If TRUE (checck-ring) then check whether the ring is BEACONING after opening the good TAU's (This check takes fibTmuFunctOk2BeaconRun milli sec. and not needed in most cases). Values: 1 - FALSE, 2 - TRUE. Factory default: FALSE. To change this object, load 'fibTmuFunctCheckAogTauPerm' into non-volatile ram. The value written into non volatile memory is loaded into the current value only after reset.

What is fibTmuFunctCheckAogTauRun?

This is the run-time (currently effective) value of whether, during BRUTAL recovery (single problem), to check if the ring is beaconing after opening the good TAUs (a check that takes about fibTmuFunctOk2BeaconRun's worth of time and usually isn't needed). Valid range is a boolean (FALSE/TRUE); factory default is FALSE. This is a read-only snapshot of what's actually in effect right now -- to change it, an admin must set fibTmuFunctCheckAogTauPerm and then reset the system, since the new value only takes effect in this Run object after a reset. Admins enable this only if recovery needs an extra beaconing check after re-opening the known-good TAUs, at the cost of a slower recovery cycle.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22.60.8.1.8
snmpwalk -v2c -c public <target> TMU-MIB::fibTmuFunctCheckAogTauRun

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22.60.8.1.8.1
snmpget -v2c -c public <target> TMU-MIB::fibTmuFunctCheckAogTauRun.1

Start monitoring Legacy networking equipment, enterprise OID 22 fibronics (firmware inventory/fault-handling status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the TMU-MIB::fibTmuFunctCheckAogTauRun OID value, configure state conditions and alerts, and monitor any Legacy networking equipment, enterprise OID 22 fibronics (firmware inventory/fault-handling status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22spartacusCMU-MIB
Numeric OIDNameModule
1.3.6.1.4.1.22.60tmuTMU-MIB
1.3.6.1.4.1.22.60.8tmuFunctionTMU-MIB
1.3.6.1.4.1.22.60.8.1fibTmuFunctRtpGrpVrsRunTMU-MIB
1.3.6.1.4.1.22.60.8.1.8fibTmuFunctCheckAogTauRunTMU-MIB