All MIBs › StorageManagement-MIB › fanProbeCurrValue
fanProbeCurrValue
Module: StorageManagement-MIB
OID (symbolic): StorageManagement-MIB::fanProbeCurrValue
OID (numeric): 1.3.6.1.4.1.674.10893.1.20.130.7.1.11
Node type: OBJECT-TYPE
Type: DisplayString
Access: read-only
Description: The current speed of the fan.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 snmpwalk -v2c -c public <target> StorageManagement-MIB::fanProbeCurrValue
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10893.1.20.130.7.1.11.1 snmpget -v2c -c public <target> StorageManagement-MIB::fanProbeCurrValue.1
Start monitoring storage array / NAS / SAN controller (volume provisioning/disk health status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the StorageManagement-MIB::fanProbeCurrValue OID value, configure state conditions and alerts, and monitor any storage array / NAS / SAN controller (volume provisioning/disk health status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.674 | dell | ArrayManager-MIB |
| 1.3.6.1.4.1.674.10893 | storage | ArrayManager-MIB |
| 1.3.6.1.4.1.674.10893.1 | software | ArrayManager-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.674.10893.1.20 | storageManagement | StorageManagement-MIB |
| 1.3.6.1.4.1.674.10893.1.20.130 | physicalDevices | StorageManagement-MIB |
| 1.3.6.1.4.1.674.10893.1.20.130.7 | fanTable | StorageManagement-MIB |
| 1.3.6.1.4.1.674.10893.1.20.130.7.1 | fanEntry | StorageManagement-MIB |
| 1.3.6.1.4.1.674.10893.1.20.130.7.1.11 | fanProbeCurrValue | StorageManagement-MIB |