All MIBs › StorageManagement-MIB › arrayDiskState
arrayDiskState
Module: StorageManagement-MIB
OID (symbolic): StorageManagement-MIB::arrayDiskState
OID (numeric): 1.3.6.1.4.1.674.10893.1.20.130.4.1.4
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: The current condition of the array disk. Possible states: 0: Unknown 1: Ready - Available for use, but no RAID configuration has been assigned. 2: Failed - Not operational. 3: Online - Operational. RAID configuration has been assigned. 4: Offline - The drive is not available to the RAID controller. 6: Degraded - Refers to a fault-tolerant array/virtual disk that has a failed disk. 7: Recovering - Refers to state of recovering from bad blocks on disks. 11: Removed - Indicates that array disk has been removed. 13: Non-RAID - Indicates that array disk is not a RAID capable disk 14: Not Ready - Applicable for PCIeSSD devices indicating that the device is in locked state 15: Resynching - Indicates one of the following types of disk operations: Transform Type, Reconfiguration, and Check Consistency. 22: Replacing - Indicates copyback operation is in progress. 23: Spinning Down - Transit state when the physical disk is spinning down for physical disk power management. 24: Rebuild 25: No Media - CD-ROM or removable disk has no media. 26: Formatting - In the process of formatting. 28: Diagnostics - Diagnostics are running. 34: Predictive failure 35: Initializing: Applies only to virtual disks on PERC, PERC 2/SC, and PERC 2/DC controllers. 39: Foreign 40: Clear 41: Unsupported 53: Incompatible 56: Read Only - Applicable for PCIeSSD devices. Indicates that device has reached read-only state
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 snmpwalk -v2c -c public <target> StorageManagement-MIB::arrayDiskState
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10893.1.20.130.4.1.4.1 snmpget -v2c -c public <target> StorageManagement-MIB::arrayDiskState.1
Start monitoring storage array / NAS / SAN controller (volume provisioning/disk health status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the StorageManagement-MIB::arrayDiskState OID value, configure state conditions and alerts, and monitor any storage array / NAS / SAN controller (volume provisioning/disk health status) from a single console.
OID Breakdown
Upper-level ancestors (9 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.674 | dell | ArrayManager-MIB |
| 1.3.6.1.4.1.674.10893 | storage | ArrayManager-MIB |
| 1.3.6.1.4.1.674.10893.1 | software | ArrayManager-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.674.10893.1.20 | storageManagement | StorageManagement-MIB |
| 1.3.6.1.4.1.674.10893.1.20.130 | physicalDevices | StorageManagement-MIB |
| 1.3.6.1.4.1.674.10893.1.20.130.4 | arrayDiskTable | StorageManagement-MIB |
| 1.3.6.1.4.1.674.10893.1.20.130.4.1 | arrayDiskEntry | StorageManagement-MIB |
| 1.3.6.1.4.1.674.10893.1.20.130.4.1.4 | arrayDiskState | StorageManagement-MIB |