StorageManagement-MIB :: arrayDiskSmartAlertIndication

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › StorageManagement-MIB › arrayDiskSmartAlertIndication

arrayDiskSmartAlertIndication

Module: StorageManagement-MIB

OID (symbolic): StorageManagement-MIB::arrayDiskSmartAlertIndication

OID (numeric): 1.3.6.1.4.1.674.10893.1.20.130.4.1.31

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Indicated whether the disk has received a predictive failure. Possible values: 1: No - disk has not received a predictive failure alert 2: Yes - disk has received a predictive failure alert

What is arrayDiskSmartAlertIndication?

Reports whether the drive's SMART monitoring has raised a predictive-failure alert: No(1) means none has been received, Yes(2) means the drive has flagged itself as likely to fail soon. Storage-health dashboards treat Yes(2) as a trigger to schedule proactive drive replacement before an outright failure.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.674.10893.1.20.130.4.1.31
snmpwalk -v2c -c public <target> StorageManagement-MIB::arrayDiskSmartAlertIndication

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.674.10893.1.20.130.4.1.31.1
snmpget -v2c -c public <target> StorageManagement-MIB::arrayDiskSmartAlertIndication.1

Start monitoring storage array / NAS / SAN controller (volume provisioning/disk health status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the StorageManagement-MIB::arrayDiskSmartAlertIndication OID value, configure state conditions and alerts, and monitor any storage array / NAS / SAN controller (volume provisioning/disk health status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.674dellArrayManager-MIB
1.3.6.1.4.1.674.10893storageArrayManager-MIB
1.3.6.1.4.1.674.10893.1softwareArrayManager-MIB
Numeric OIDNameModule
1.3.6.1.4.1.674.10893.1.20storageManagementStorageManagement-MIB
1.3.6.1.4.1.674.10893.1.20.130physicalDevicesStorageManagement-MIB
1.3.6.1.4.1.674.10893.1.20.130.4arrayDiskTableStorageManagement-MIB
1.3.6.1.4.1.674.10893.1.20.130.4.1arrayDiskEntryStorageManagement-MIB
1.3.6.1.4.1.674.10893.1.20.130.4.1.31arrayDiskSmartAlertIndicationStorageManagement-MIB