SYMMSYNCE :: syncEOutputQLMode

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SYMMSYNCE › syncEOutputQLMode

syncEOutputQLMode

Module: SYMMSYNCE

OID (symbolic): SYMMSYNCE::syncEOutputQLMode

OID (numeric): 1.3.6.1.4.1.9070.1.2.5.2.8.2.1.1.4

Node type: OBJECT-TYPE

Type: SYNCEPQLMODE

Access: read-write

Description: SyncE output port output QL mode. It can be unidirectional or bidirectional. In the unidirectional mode, the outgoing QL value is independent of the incoming QL value. In the bidirectional mode, the outgoing QL value is changed to DNU if it is the same as the incoming QL value.

What is syncEOutputQLMode?

This read-write value sets the SyncE output port's QL mode to bidirectional or unidirectional (SYNCEPQLMODE), defaulting to bidirectional; in unidirectional mode the outgoing QL value is independent of the incoming QL, while in bidirectional mode the outgoing QL is changed to DNU (Do Not Use) if it matches the incoming QL. Admins set this mode to control loop-prevention behavior in the synchronization network topology. For example, leaving syncEOutputQLMode at its default bidirectional(1) on a ring topology helps prevent the device from advertising back a quality level it just received, avoiding timing loops.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.2.8.2.1.1.4
snmpwalk -v2c -c public <target> SYMMSYNCE::syncEOutputQLMode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.9070.1.2.5.2.8.2.1.1.4.1
snmpget -v2c -c public <target> SYMMSYNCE::syncEOutputQLMode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.9070.1.2.5.2.8.2.1.1.4.1 s <value>

Start monitoring Symmetricom timing/synchronization equipment, carrier-grade Ethernet network element (SyncE/ESMC quality-level status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SYMMSYNCE::syncEOutputQLMode OID value, configure state conditions and alerts, and monitor any Symmetricom timing/synchronization equipment, carrier-grade Ethernet network element (SyncE/ESMC quality-level status) from a single console.

OID Breakdown

Upper-level ancestors (11 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.9070symmetricomSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1symmNetworkManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2symmSnmpManagementSYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5symmCommonModelV1SYMM-COMMON-SMI
1.3.6.1.4.1.9070.1.2.5.2symmPhysicalSignalSYMM-COMMON-SMI
Numeric OIDNameModule
1.3.6.1.4.1.9070.1.2.5.2.8symmSyncESYMMSYNCE
1.3.6.1.4.1.9070.1.2.5.2.8.2syncEConfigSYMMSYNCE
1.3.6.1.4.1.9070.1.2.5.2.8.2.1syncEOutputConfigTableSYMMSYNCE
1.3.6.1.4.1.9070.1.2.5.2.8.2.1.1syncEOutputConfigEntrySYMMSYNCE
1.3.6.1.4.1.9070.1.2.5.2.8.2.1.1.4syncEOutputQLModeSYMMSYNCE