SWITCH-FILTER-MIB :: rcAclFilterCounterStatisticUnit

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SWITCH-FILTER-MIB › rcAclFilterCounterStatisticUnit

rcAclFilterCounterStatisticUnit

Module: SWITCH-FILTER-MIB

OID (symbolic): SWITCH-FILTER-MIB::rcAclFilterCounterStatisticUnit

OID (numeric): 1.3.6.1.4.1.8886.6.1.14.1.4.1.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: the filter statistics unit.

What is rcAclFilterCounterStatisticUnit?

This reports which unit, bytes or packets, this particular hardware statistics resource for the filter entry is actually counting. An admin checks this to correctly interpret the raw counter value in cases where the underlying hardware counter can be configured to count either bytes or packets but not necessarily both simultaneously. For example, seeing this report bytes tells the admin that the associated hardware counter reflects byte volume, and a separate mechanism is needed to also see packet counts.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.8886.6.1.14.1.4.1.4
snmpwalk -v2c -c public <target> SWITCH-FILTER-MIB::rcAclFilterCounterStatisticUnit

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.8886.6.1.14.1.4.1.4.1
snmpget -v2c -c public <target> SWITCH-FILTER-MIB::rcAclFilterCounterStatisticUnit.1

Start monitoring Raisecom managed Ethernet switch (Layer 2/3 traffic filter rule config) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SWITCH-FILTER-MIB::rcAclFilterCounterStatisticUnit OID value, configure state conditions and alerts, and monitor any Raisecom managed Ethernet switch (Layer 2/3 traffic filter rule config) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.8886raisecomRAISECOM-BASE-MIB
1.3.6.1.4.1.8886.6iscomSeriesRAISECOM-BASE-MIB
1.3.6.1.4.1.8886.6.1iscomSwitchRAISECOM-BASE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.8886.6.1.14rcFilterSWITCH-FILTER-MIB
1.3.6.1.4.1.8886.6.1.14.1rcAclFilterSWITCH-FILTER-MIB
1.3.6.1.4.1.8886.6.1.14.1.4rcAclFilterStatisticsTableSWITCH-FILTER-MIB
1.3.6.1.4.1.8886.6.1.14.1.4.1rcAclFilterStatisticsEntrySWITCH-FILTER-MIB
1.3.6.1.4.1.8886.6.1.14.1.4.1.4rcAclFilterCounterStatisticUnitSWITCH-FILTER-MIB