SW-COMMON-MIB :: swL2DevAlarmPowerTemperature

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SW-COMMON-MIB › swL2DevAlarmPowerTemperature

swL2DevAlarmPowerTemperature

Module: SW-COMMON-MIB

OID (symbolic): SW-COMMON-MIB::swL2DevAlarmPowerTemperature

OID (numeric): 1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1.2.5.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Controls temperature error state in power module.

What is swL2DevAlarmPowerTemperature?

This object enables or disables the alarm for over-temperature conditions on the indexed power module. Admins enable it so a power supply running hot triggers a trap, giving early warning before the PSU derates or fails. With this set to enabled(3) on power module 1, the switch raises an alarm if that PSU's internal temperature sensor crosses its threshold.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1.2.5.1.2
snmpwalk -v2c -c public <target> SW-COMMON-MIB::swL2DevAlarmPowerTemperature

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1.2.5.1.2.1
snmpget -v2c -c public <target> SW-COMMON-MIB::swL2DevAlarmPowerTemperature.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1.2.5.1.2.1 i <value>

Start monitoring D-Link ES2000 'Golf' series switch (Marconi-branded OEM, shared object definitions) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SW-COMMON-MIB::swL2DevAlarmPowerTemperature OID value, configure state conditions and alerts, and monitor any D-Link ES2000 'Golf' series switch (Marconi-branded OEM, shared object definitions) from a single console.

OID Breakdown

Upper-level ancestors (13 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.326foreCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2systemsCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.20ethernetCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.20.1edgeCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.20.1.2golfCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.20.1.2.2golfcommonCOMMON-GOLF-MIB
1.3.6.1.4.1.326.2.20.1.2.2.2fore_mgmtCOMMON-GOLF-MIB
Numeric OIDNameModule
1.3.6.1.4.1.326.2.20.1.2.2.2.28es2000MgmtSW-COMMON-MIB
1.3.6.1.4.1.326.2.20.1.2.2.2.28.2swL2MgmtSW-COMMON-MIB
1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1swL2DevMgmtSW-COMMON-MIB
1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1.2swL2DevAlarmSW-COMMON-MIB
1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1.2.5swL2DevAlarmPowerTableSW-COMMON-MIB
1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1.2.5.1swL2DevAlarmPowerEntrySW-COMMON-MIB
1.3.6.1.4.1.326.2.20.1.2.2.2.28.2.1.2.5.1.2swL2DevAlarmPowerTemperatureSW-COMMON-MIB