SVRMGT-MIB :: svrThrCpuUsage

MIB Reference — IPNetwork Monitor

All MIBsSVRMGT-MIBsvrThrCpuUsage

svrThrCpuUsage

Module: SVRMGT-MIB

OID (symbolic): SVRMGT-MIB::svrThrCpuUsage

OID (numeric): 1.3.6.1.4.1.36.2.18.22.2.0.135

Node type: NOTIFICATION-TYPE

Description:

This indicates that CPU usage has exceeded the user defined threshold. The value that caused the alarm to occur is returned in svrThrLastValue.

Examples

Send this trap to an SNMP manager — replace <manager> with the IP or hostname of your monitoring server (SNMPv2c):

snmptrap -v2c -c public <manager> '' SVRMGT-MIB::svrThrCpuUsage
snmptrap -v2c -c public <manager> '' 1.3.6.1.4.1.36.2.18.22.2.0.135

Listen for incoming traps on the manager host (-f keeps it in the foreground, -Lo prints to stdout — useful for testing):

snmptrapd -f -Lo -c /dev/null authCommunity log public

Example snmptrapd log entry:

zoo11-linux.zoo [UDP: [192.168.30.111]:62935->[192.168.30.10]:162]:
  DISMAN-EVENT-MIB::sysUpTimeInstance = Timeticks: (377654231) 43 days, 17:02:22.31
  SNMPv2-MIB::snmpTrapOID.0 = OID: SVRMGT-MIB::svrThrCpuUsage

OID Breakdown

Numeric OIDNameModule
1isoLANART-AGENT
1.3orgBIANCA-BRICK-PPP-MIB
1.3.6dodBIANCA-BRICK-PPP-MIB
1.3.6.1internetBIANCA-BRICK-PPP-MIB
1.3.6.1.4privateBIANCA-BRICK-PPP-MIB
1.3.6.1.4.1enterprisesANIROOT-MIB
1.3.6.1.4.1.36decDECATM-MIB
1.3.6.1.4.1.36.2emaDECATM-MIB
1.3.6.1.4.1.36.2.18decMIBextensionDECATM-MIB
1.3.6.1.4.1.36.2.18.22svrSystemSVRMGT-MIB
1.3.6.1.4.1.36.2.18.22.2svrMgtSVRMGT-MIB
1.3.6.1.4.1.36.2.18.22.2.0.135svrThrCpuUsageSVRMGT-MIB