SUN-HW-CTRL-MIB :: sunHwCtrlTpmForceClear

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SUN-HW-CTRL-MIB › sunHwCtrlTpmForceClear

sunHwCtrlTpmForceClear

Module: SUN-HW-CTRL-MIB

OID (symbolic): SUN-HW-CTRL-MIB::sunHwCtrlTpmForceClear

OID (numeric): 1.3.6.1.4.1.42.2.175.104.1.7.3

Node type: OBJECT-TYPE

Type: TruthValue

Access: read-write

Description: If sunHwCtrlTpmForceClear and sunHwCtrlTpmEnable are both currently true(1) during a host power on event, the TPM device state will be purged and the state of sunHwCtrlTpmForceClear will return to false(2). If sunHwCtrlTpmForceClear is currently true(1) and sunHwCtrlTpmEnable is currently false(2) during a host power on event, the TPM device will not be enabled, no action is taken with regard to the state of the TPM device, and sunHwCtrlTpmForceClear remains true(1). If sunHwCtrlTpmForceClear is currently false(2) and sunHwCtrlTpmEnable is currently true(1) during a host power on event, the TPM device will be enabled, no action is taken with regard to the state of the TPM device, and sunHwCtrlTpmForceClear remains false(2). When sunHwCtrlTpmEnable is set to false(2), no changes to sunHwCtrlTpmForceClear will succeed.

What is sunHwCtrlTpmForceClear?

Requests that the TPM's state be purged at the next host power-on if the TPM is also enabled; the flag automatically resets to false once the clear has actually been performed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.42.2.175.104.1.7.3
snmpwalk -v2c -c public <target> SUN-HW-CTRL-MIB::sunHwCtrlTpmForceClear

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.42.2.175.104.1.7.3.1
snmpget -v2c -c public <target> SUN-HW-CTRL-MIB::sunHwCtrlTpmForceClear.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.42.2.175.104.1.7.3.1 s <value>

Start monitoring Sun/Oracle server hardware managed via ILOM (power supply/power-budget status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SUN-HW-CTRL-MIB::sunHwCtrlTpmForceClear OID value, configure state conditions and alerts, and monitor any Sun/Oracle server hardware managed via ILOM (power supply/power-budget status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.42sunAGENT-STATS-MIB2
1.3.6.1.4.1.42.2prodAGENT-STATS-MIB2
Numeric OIDNameModule
1.3.6.1.4.1.42.2.175ilomSUN-HW-CTRL-MIB
1.3.6.1.4.1.42.2.175.104sunHwCtrlMIBSUN-HW-CTRL-MIB
1.3.6.1.4.1.42.2.175.104.1sunHwCtrlMIBObjectsSUN-HW-CTRL-MIB
1.3.6.1.4.1.42.2.175.104.1.7sunHwCtrlTPMSUN-HW-CTRL-MIB
1.3.6.1.4.1.42.2.175.104.1.7.3sunHwCtrlTpmForceClearSUN-HW-CTRL-MIB