SUB10SYSTEMS-MIB :: sub10UnitMgmtAlarmMonitorIntvl

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsSUB10SYSTEMS-MIBsub10UnitMgmtAlarmMonitorIntvl

sub10UnitMgmtAlarmMonitorIntvl

Module: SUB10SYSTEMS-MIB

OID (symbolic): SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmMonitorIntvl

OID (numeric): 1.3.6.1.4.1.39003.3.2.6.1.1.6

Node type: OBJECT-TYPE

Type: Unsigned32

Access: read-write

Description: The interval in seconds when the measured object is to be read and compared with the raise and clear thresholds. An alarm cannot be raised or cleared quicker than the configured interval. Please also see related sub10UnitMgmtAlarmRaiseIntvls and sub10UnitMgmtAlarmClearIntvls objects which also affect when alarms are raised and cleared. This object should be set appropriately for the measured object to be monitored (see sub10UnitMgmtAlarmRaiseMeasObject) and the resulting alarm to be raised and cleared (see sub10UnitMgmtAlarmName). This also affects the forwarding of alarms for example as SNMP notifications.

Higher severity alarms may have a shorter interval than those at a lower severity. The correct setting of sub10UnitMgmtAlarmMonitorIntvl and related objects sub10UnitMgmtAlarmRaiseIntvls and sub10UnitMgmtAlarmClearIntvls are important to avoid potential network loading caused by alarm storms.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.39003.3.2.6.1.1.6
snmpwalk -v2c -c public <target> SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmMonitorIntvl

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.39003.3.2.6.1.1.6.1
snmpget -v2c -c public <target> SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmMonitorIntvl.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.39003.3.2.6.1.1.6.1 i <value>

SNMPv3 example:

snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sub10UnitMgmtAlarmMonitorIntvl.1

Start monitoring Sub10 Systems point-to-point microwave radio link terminal (firmware/identity status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmMonitorIntvl OID value, configure state conditions and alerts, and monitor any Sub10 Systems point-to-point microwave radio link terminal (firmware/identity status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.39003sub10SystemsSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3sub10UnitSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2sub10UnitMgmtSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2.6sub10UnitMgmtAlarmsSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2.6.1sub10UnitMgmtAlarmTableSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2.6.1.1sub10UnitMgmtAlarmEntrySUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2.6.1.1.6sub10UnitMgmtAlarmMonitorIntvlSUB10SYSTEMS-MIB