All MIBs › SUB10SYSTEMS-MIB › sub10UnitMgmtAlarmMonitorIntvl
sub10UnitMgmtAlarmMonitorIntvl
Module: SUB10SYSTEMS-MIB
OID (symbolic): SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmMonitorIntvl
OID (numeric): 1.3.6.1.4.1.39003.3.2.6.1.1.6
Node type: OBJECT-TYPE
Type: Unsigned32
Access: read-write
Description: The interval in seconds when the measured object is to be read and compared with the raise and clear thresholds. An alarm cannot be raised or cleared quicker than the configured interval. Please also see related sub10UnitMgmtAlarmRaiseIntvls and sub10UnitMgmtAlarmClearIntvls objects which also affect when alarms are raised and cleared. This object should be set appropriately for the measured object to be monitored (see sub10UnitMgmtAlarmRaiseMeasObject) and the resulting alarm to be raised and cleared (see sub10UnitMgmtAlarmName). This also affects the forwarding of alarms for example as SNMP notifications.
Higher severity alarms may have a shorter interval than those at a lower severity. The correct setting of sub10UnitMgmtAlarmMonitorIntvl and related objects sub10UnitMgmtAlarmRaiseIntvls and sub10UnitMgmtAlarmClearIntvls are important to avoid potential network loading caused by alarm storms.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.39003.3.2.6.1.1.6 snmpwalk -v2c -c public <target> SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmMonitorIntvl
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.39003.3.2.6.1.1.6.1 snmpget -v2c -c public <target> SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmMonitorIntvl.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.39003.3.2.6.1.1.6.1 i <value>
SNMPv3 example:
snmpget -v3 -l authPriv -u snmpv3-user -a SHA -A "AuthPassword1" -x AES -X "PrivPassword1" <target> sub10UnitMgmtAlarmMonitorIntvl.1
Start monitoring Sub10 Systems point-to-point microwave radio link terminal (firmware/identity status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmMonitorIntvl OID value, configure state conditions and alerts, and monitor any Sub10 Systems point-to-point microwave radio link terminal (firmware/identity status) from a single console.
OID Breakdown
Upper-level ancestors (6 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.39003 | sub10Systems | SUB10SYSTEMS-MIB |
| 1.3.6.1.4.1.39003.3 | sub10Unit | SUB10SYSTEMS-MIB |
| 1.3.6.1.4.1.39003.3.2 | sub10UnitMgmt | SUB10SYSTEMS-MIB |
| 1.3.6.1.4.1.39003.3.2.6 | sub10UnitMgmtAlarms | SUB10SYSTEMS-MIB |
| 1.3.6.1.4.1.39003.3.2.6.1 | sub10UnitMgmtAlarmTable | SUB10SYSTEMS-MIB |
| 1.3.6.1.4.1.39003.3.2.6.1.1 | sub10UnitMgmtAlarmEntry | SUB10SYSTEMS-MIB |
| 1.3.6.1.4.1.39003.3.2.6.1.1.6 | sub10UnitMgmtAlarmMonitorIntvl | SUB10SYSTEMS-MIB |