SUB10SYSTEMS-MIB :: sub10UnitMgmtAlarmClearOper

MIB Reference — IPNetwork Monitor · Updated September 12, 2026

All MIBsSUB10SYSTEMS-MIBsub10UnitMgmtAlarmClearOper

sub10UnitMgmtAlarmClearOper

Module: SUB10SYSTEMS-MIB

OID (symbolic): SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmClearOper

OID (numeric): 1.3.6.1.4.1.39003.3.2.6.1.1.9

Node type: OBJECT-TYPE

Type: Sub10AlarmOperation

Access: read-write

Description: Type of operation which determines when an alarm is to be cleared.

Definition of each type is as follows:

lt - Measured objects value is less than clear threshold gt - Measured objects value is greater than clear threshold le - Measured objects value is less than or equal to clear threshold ge - Measured objects value is greater than or equal to clear threshold eq - Measured objects value is equal to clear threshold neq - Measured objects value is not equal to clear threshold

The alarm operation defines how to apply the configured thresholds when clearing the alarm. This defines whether the alarm is cleared when the measured object value crosses the threshold from low to high or from high to low or if the measured value hits a certain value or not.

Example:

Alarm Name Alarm Threshold Clear Operation High Temperature 60 le Low Temperature -30 gt

Low Temperature Alarm is cleared when the measured temperature is lower or equal to 60 and Low Temperature cleared when the measured temperature is greater than -30.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.39003.3.2.6.1.1.9
snmpwalk -v2c -c public <target> SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmClearOper

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.39003.3.2.6.1.1.9.1
snmpget -v2c -c public <target> SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmClearOper.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.39003.3.2.6.1.1.9.1 s <value>

Start monitoring Sub10 Systems point-to-point microwave radio link terminal (firmware/identity status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SUB10SYSTEMS-MIB::sub10UnitMgmtAlarmClearOper OID value, configure state conditions and alerts, and monitor any Sub10 Systems point-to-point microwave radio link terminal (firmware/identity status) from a single console.

OID Breakdown

Upper-level ancestors (6 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
Numeric OIDNameModule
1.3.6.1.4.1.39003sub10SystemsSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3sub10UnitSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2sub10UnitMgmtSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2.6sub10UnitMgmtAlarmsSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2.6.1sub10UnitMgmtAlarmTableSUB10SYSTEMS-MIB
1.3.6.1.4.1.39003.3.2.6.1.1sub10UnitMgmtAlarmEntrySUB10SYSTEMS-MIB