SSPM-MIB :: sspmSinkLastSequenceInvalid

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSSPM-MIBsspmSinkLastSequenceInvalid

sspmSinkLastSequenceInvalid

Module: SSPM-MIB

OID (symbolic): SSPM-MIB::sspmSinkLastSequenceInvalid

OID (numeric): 1.3.6.1.2.1.16.28.1.5.1.1.9

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: The number of packets that arrived whose sequence number was not one plus the value of sspmSinkLastSequenceNumber.

What is sspmSinkLastSequenceInvalid?

A running count of received packets whose sequence number wasn't exactly one more than the previous packet's, the sink's primary packet-loss/reordering indicator that an admin watches to judge test traffic quality.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.16.28.1.5.1.1.9
snmpwalk -v2c -c public <target> SSPM-MIB::sspmSinkLastSequenceInvalid

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.16.28.1.5.1.1.9.1
snmpget -v2c -c public <target> SSPM-MIB::sspmSinkLastSequenceInvalid.1

Start monitoring vendor-neutral, standards-based MIB (RFC 4149), network performance-measurement probe/test point with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SSPM-MIB::sspmSinkLastSequenceInvalid OID value, configure state conditions and alerts, and monitor any vendor-neutral, standards-based MIB (RFC 4149), network performance-measurement probe/test point from a single console.

How to Use in IPNetwork Monitor

Select a device implementing SSPM-MIB as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type sspmSinkLastSequenceInvalid into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The number of packets that arrived whose sequence number was not one plus the value of sspmSinkLastSequenceNumber. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.16rmonLBHUB-BOOM-MIB
Numeric OIDNameModule
1.3.6.1.2.1.16.28sspmMIBSSPM-MIB
1.3.6.1.2.1.16.28.1sspmMIBObjectsSSPM-MIB
1.3.6.1.2.1.16.28.1.5sspmSinkSSPM-MIB
1.3.6.1.2.1.16.28.1.5.1sspmSinkTableSSPM-MIB
1.3.6.1.2.1.16.28.1.5.1.1sspmSinkEntrySSPM-MIB
1.3.6.1.2.1.16.28.1.5.1.1.9sspmSinkLastSequenceInvalidSSPM-MIB