SPC200 :: plcSNAnalyserMinSignal

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SPC200 › plcSNAnalyserMinSignal

plcSNAnalyserMinSignal

Module: SPC200

OID (symbolic): SPC200::plcSNAnalyserMinSignal

OID (numeric): 1.3.6.1.4.1.22764.1.1.2.4.2.1.1

Node type: OBJECT-TYPE

Type: OCTET STRING

Access: read-only

Description: Minimum signal measured over several samples for the associated carrier wave entry. The value is expressed in Glomer� which can be converted in dBm/Hz using the following formula: dBm/Hz = 19*log10(Glomer�) - 113

What is plcSNAnalyserMinSignal?

An OCTET STRING giving the minimum signal level measured over several samples for the indexed carrier wave, expressed in a raw 'Glomer' unit convertible to dBm/Hz via the formula given in the MIB (19*log10(Glomer)-113). An admin running the spectrum analyser reads this to find the weakest observed signal point on that carrier.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22764.1.1.2.4.2.1.1
snmpwalk -v2c -c public <target> SPC200::plcSNAnalyserMinSignal

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22764.1.1.2.4.2.1.1.1
snmpget -v2c -c public <target> SPC200::plcSNAnalyserMinSignal.1

Start monitoring powerline communication (PLC) network adapter/bridge (master/slave BSS role, sync-band/Ethernet interface status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SPC200::plcSNAnalyserMinSignal OID value, configure state conditions and alerts, and monitor any powerline communication (PLC) network adapter/bridge (master/slave BSS role, sync-band/Ethernet interface status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22764spidcomSPIDCOM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.22764.1spc200MIBSPC200
1.3.6.1.4.1.22764.1.1plcSPC200
1.3.6.1.4.1.22764.1.1.2plcObjectsSPC200
1.3.6.1.4.1.22764.1.1.2.4plcSNAnalyserSPC200
1.3.6.1.4.1.22764.1.1.2.4.2plcSNAnalyserTableSPC200
1.3.6.1.4.1.22764.1.1.2.4.2.1plcSNAnalyserEntrySPC200
1.3.6.1.4.1.22764.1.1.2.4.2.1.1plcSNAnalyserMinSignalSPC200