All MIBs › SPC200 › plcNodeAdaptsCarrier1
plcNodeAdaptsCarrier1
Module: SPC200
OID (symbolic): SPC200::plcNodeAdaptsCarrier1
OID (numeric): 1.3.6.1.4.1.22764.1.1.2.3.8.1.3
Node type: OBJECT-TYPE
Type: AdaptValue
Access: read-only
Description: The adapt level of the first carrier of the group.
What is plcNodeAdaptsCarrier1?
A read-only AdaptValue (0-8191) giving the adapt (equalization) level of the first carrier in the indexed group/band. Adapt level reflects how much the modem is compensating that carrier for line conditions, so unusually high values flag a noisy or attenuated carrier.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22764.1.1.2.3.8.1.3 snmpwalk -v2c -c public <target> SPC200::plcNodeAdaptsCarrier1
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.22764.1.1.2.3.8.1.3.1 snmpget -v2c -c public <target> SPC200::plcNodeAdaptsCarrier1.1
Start monitoring powerline communication (PLC) network adapter/bridge (master/slave BSS role, sync-band/Ethernet interface status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SPC200::plcNodeAdaptsCarrier1 OID value, configure state conditions and alerts, and monitor any powerline communication (PLC) network adapter/bridge (master/slave BSS role, sync-band/Ethernet interface status) from a single console.
OID Breakdown
Upper-level ancestors (7 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.22764 | spidcom | SPIDCOM-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.22764.1 | spc200MIB | SPC200 |
| 1.3.6.1.4.1.22764.1.1 | plc | SPC200 |
| 1.3.6.1.4.1.22764.1.1.2 | plcObjects | SPC200 |
| 1.3.6.1.4.1.22764.1.1.2.3 | plcNodeConfiguration | SPC200 |
| 1.3.6.1.4.1.22764.1.1.2.3.8 | plcNodeAdaptsTable | SPC200 |
| 1.3.6.1.4.1.22764.1.1.2.3.8.1 | plcNodeAdaptsEntry | SPC200 |
| 1.3.6.1.4.1.22764.1.1.2.3.8.1.3 | plcNodeAdaptsCarrier1 | SPC200 |