SPC200 :: plcMasterBssId

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SPC200 › plcMasterBssId

plcMasterBssId

Module: SPC200

OID (symbolic): SPC200::plcMasterBssId

OID (numeric): 1.3.6.1.4.1.22764.1.1.2.6.1

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: The value of the master Bss Id

What is plcMasterBssId?

A read-write INTEGER (0-99) setting the BSS (Basic Service Set) identifier this node uses when acting as master, letting an installer group multiple PLC networks that share the same physical medium without interfering with each other.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.22764.1.1.2.6.1
snmpwalk -v2c -c public <target> SPC200::plcMasterBssId

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.22764.1.1.2.6.1.1
snmpget -v2c -c public <target> SPC200::plcMasterBssId.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.22764.1.1.2.6.1.1 i <value>

Start monitoring powerline communication (PLC) network adapter/bridge (master/slave BSS role, sync-band/Ethernet interface status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SPC200::plcMasterBssId OID value, configure state conditions and alerts, and monitor any powerline communication (PLC) network adapter/bridge (master/slave BSS role, sync-band/Ethernet interface status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.22764spidcomSPIDCOM-MIB
Numeric OIDNameModule
1.3.6.1.4.1.22764.1spc200MIBSPC200
1.3.6.1.4.1.22764.1.1plcSPC200
1.3.6.1.4.1.22764.1.1.2plcObjectsSPC200
1.3.6.1.4.1.22764.1.1.2.6plcBssIdSPC200
1.3.6.1.4.1.22764.1.1.2.6.1plcMasterBssIdSPC200