SNI-SERVER-CONTROL-MIB :: upsTimeOnBatterySeconds

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SNI-SERVER-CONTROL-MIB › upsTimeOnBatterySeconds

upsTimeOnBatterySeconds

Module: SNI-SERVER-CONTROL-MIB

OID (symbolic): SNI-SERVER-CONTROL-MIB::upsTimeOnBatterySeconds

OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.8

Node type: OBJECT-TYPE

Type: Counter

Access: read-only

Description: Time (in seconds) the UPS is running on battery since power fail (will be cleared on power recovery)

What is upsTimeOnBatterySeconds?

Read-only counter of seconds this UPS has been running on battery since the current power failure began, cleared once power is restored. The live counter an admin watches during an outage to see how much of upsDischargeTime's runway has already been consumed.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.8
snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::upsTimeOnBatterySeconds

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.8.1
snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::upsTimeOnBatterySeconds.1

Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::upsTimeOnBatterySeconds OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
1.3.6.1.4.1.231.2.10sniExtensionsDESKTRAP-MIB
1.3.6.1.4.1.231.2.10.2sniServerMgmtFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2sniCommonFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2.5sniServerControlFSC-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.10.2.2.5.12uninterruptablePowerSupplySNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.12.2upsInfosTableSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1upsInfosSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.12.2.1.8upsTimeOnBatterySecondsSNI-SERVER-CONTROL-MIB