All MIBs › SNI-SERVER-CONTROL-MIB › stdSetupPostErrorHalt
stdSetupPostErrorHalt
Module: SNI-SERVER-CONTROL-MIB
OID (symbolic): SNI-SERVER-CONTROL-MIB::stdSetupPostErrorHalt
OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.7.3
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Describes what to do when a POST error has occured (halt on any error, no halt on any error...). The values unknown(1) and other(9) cannot be set, a SET will deliver 'badValue'.
What is stdSetupPostErrorHalt?
Read-write POST error-handling policy: halt-on-any-error(2) stops boot on any POST error, no-halt-on-any-error(3) continues booting anyway (unknown(1) and other(9) not settable). Data centers often set this to no-halt so a non-fatal POST warning (e.g. one missing fan) doesn't leave an unattended server stuck at a BIOS prompt.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.7.3 snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::stdSetupPostErrorHalt
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.7.3.1 snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::stdSetupPostErrorHalt.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.231.2.10.2.2.5.7.3.1 i <value>
Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::stdSetupPostErrorHalt OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.2 | sniProductMibs | Application-Monitoring-MIB |
| 1.3.6.1.4.1.231.2.10 | sniExtensions | DESKTRAP-MIB |
| 1.3.6.1.4.1.231.2.10.2 | sniServerMgmt | FSC-SWITCH-MIB |
| 1.3.6.1.4.1.231.2.10.2.2 | sniCommon | FSC-SWITCH-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.5 | sniServerControl | FSC-SWITCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.2.10.2.2.5.7 | standardBiosSetup | SNI-SERVER-CONTROL-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.5.7.3 | stdSetupPostErrorHalt | SNI-SERVER-CONTROL-MIB |