SNI-SERVER-CONTROL-MIB :: srvSetupRebootFailAction

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SNI-SERVER-CONTROL-MIB › srvSetupRebootFailAction

srvSetupRebootFailAction

Module: SNI-SERVER-CONTROL-MIB

OID (symbolic): SNI-SERVER-CONTROL-MIB::srvSetupRebootFailAction

OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.8.11

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Describes the action on a specified number of failed reboot retries (srvSetupMaxRestartRetries=0): unknown(1) - diagnostic system cannot be determined (cannot be SET) switch-off(2) - no diag system, final power-off ide-diag-disk(3) - boot diag system from IDE disk no-diag-system(4) - no diag system available remote-image-disk(5) - boot from remote image (over LAN) pxe(6) - boot from PXE (Preboot eXecution Environment) rsb-usb(7) - boot from RSB remote source (via USB interface) bmc-remote(8) - boot from BMC from remote storage This value is also the source to be booted from when object 'stdSetupBootSource' is set to 'diag-system'.

What is srvSetupRebootFailAction?

Read-write fallback action once srvSetupMaxRestartRetries is exhausted: switch-off(2), ide-diag-disk(3), remote-image-disk(5), pxe(6), rsb-usb(7) or bmc-remote(8) (unknown(1) not settable). This is what an admin configures so a server that keeps failing to boot lands in a controlled diagnostic/PXE state instead of endlessly reboot-looping.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.8.11
snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::srvSetupRebootFailAction

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.8.11.1
snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::srvSetupRebootFailAction.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.2.10.2.2.5.8.11.1 i <value>

Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::srvSetupRebootFailAction OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
1.3.6.1.4.1.231.2.10sniExtensionsDESKTRAP-MIB
1.3.6.1.4.1.231.2.10.2sniServerMgmtFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2sniCommonFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2.5sniServerControlFSC-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.10.2.2.5.8serverBiosSetupSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.8.11srvSetupRebootFailActionSNI-SERVER-CONTROL-MIB