All MIBs › SNI-SERVER-CONTROL-MIB › srvSetupRebootFailAction
srvSetupRebootFailAction
Module: SNI-SERVER-CONTROL-MIB
OID (symbolic): SNI-SERVER-CONTROL-MIB::srvSetupRebootFailAction
OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.8.11
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-write
Description: Describes the action on a specified number of failed reboot retries (srvSetupMaxRestartRetries=0): unknown(1) - diagnostic system cannot be determined (cannot be SET) switch-off(2) - no diag system, final power-off ide-diag-disk(3) - boot diag system from IDE disk no-diag-system(4) - no diag system available remote-image-disk(5) - boot from remote image (over LAN) pxe(6) - boot from PXE (Preboot eXecution Environment) rsb-usb(7) - boot from RSB remote source (via USB interface) bmc-remote(8) - boot from BMC from remote storage This value is also the source to be booted from when object 'stdSetupBootSource' is set to 'diag-system'.
What is srvSetupRebootFailAction?
Read-write fallback action once srvSetupMaxRestartRetries is exhausted: switch-off(2), ide-diag-disk(3), remote-image-disk(5), pxe(6), rsb-usb(7) or bmc-remote(8) (unknown(1) not settable). This is what an admin configures so a server that keeps failing to boot lands in a controlled diagnostic/PXE state instead of endlessly reboot-looping.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.8.11 snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::srvSetupRebootFailAction
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.8.11.1 snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::srvSetupRebootFailAction.1
Set instance 1 (SNMPv2c):
snmpset -v2c -c private <target> 1.3.6.1.4.1.231.2.10.2.2.5.8.11.1 i <value>
Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::srvSetupRebootFailAction OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.
OID Breakdown
Upper-level ancestors (12 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.2 | sniProductMibs | Application-Monitoring-MIB |
| 1.3.6.1.4.1.231.2.10 | sniExtensions | DESKTRAP-MIB |
| 1.3.6.1.4.1.231.2.10.2 | sniServerMgmt | FSC-SWITCH-MIB |
| 1.3.6.1.4.1.231.2.10.2.2 | sniCommon | FSC-SWITCH-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.5 | sniServerControl | FSC-SWITCH-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.2.10.2.2.5.8 | serverBiosSetup | SNI-SERVER-CONTROL-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.5.8.11 | srvSetupRebootFailAction | SNI-SERVER-CONTROL-MIB |