SNI-SERVER-CONTROL-MIB :: spbbuDoChargeCycle

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SNI-SERVER-CONTROL-MIB › spbbuDoChargeCycle

spbbuDoChargeCycle

Module: SNI-SERVER-CONTROL-MIB

OID (symbolic): SNI-SERVER-CONTROL-MIB::spbbuDoChargeCycle

OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.12.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: Perform a discharge/charge cycle on the backup battery. Reading this object just returns the value 0.

What is spbbuDoChargeCycle?

Optional, read-write control that, when set to recharge(1), performs a discharge/charge cycle on the backup battery to recalibrate it; reading it always returns 0. An admin runs this periodically to keep the backup battery's capacity readings accurate, similar to conditioning a laptop battery.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.12.6
snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::spbbuDoChargeCycle

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.12.6.1
snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::spbbuDoChargeCycle.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.2.10.2.2.5.12.6.1 i <value>

Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::spbbuDoChargeCycle OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
1.3.6.1.4.1.231.2.10sniExtensionsDESKTRAP-MIB
1.3.6.1.4.1.231.2.10.2sniServerMgmtFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2sniCommonFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2.5sniServerControlFSC-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.10.2.2.5.12uninterruptablePowerSupplySNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.12.6spbbuDoChargeCycleSNI-SERVER-CONTROL-MIB