SNI-SERVER-CONTROL-MIB :: sniScVoltageNumber

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SNI-SERVER-CONTROL-MIB › sniScVoltageNumber

sniScVoltageNumber

Module: SNI-SERVER-CONTROL-MIB

OID (symbolic): SNI-SERVER-CONTROL-MIB::sniScVoltageNumber

OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.2

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Power supply voltage number, index into power supply voltage table (0 based)

What is sniScVoltageNumber?

Read-only, zero-based voltage-rail index within its cabinet, completing sniScVoltageTable's composite index; the total count per cabinet is given by sieScCabinetNumberVoltages. Enumerates each individual voltage rail (e.g. 5V, 12V, 3.3V) monitored on the power supply.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.2
snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::sniScVoltageNumber

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.2.1
snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::sniScVoltageNumber.1

Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::sniScVoltageNumber OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
1.3.6.1.4.1.231.2.10sniExtensionsDESKTRAP-MIB
1.3.6.1.4.1.231.2.10.2sniServerMgmtFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2sniCommonFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2.5sniServerControlFSC-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.10.2.2.5.11powerSupplySNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.11.4sniScVoltageTableSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1sniScVoltagesSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.11.4.1.2sniScVoltageNumberSNI-SERVER-CONTROL-MIB