SNI-SERVER-CONTROL-MIB :: fanIdentification

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SNI-SERVER-CONTROL-MIB › fanIdentification

fanIdentification

Module: SNI-SERVER-CONTROL-MIB

OID (symbolic): SNI-SERVER-CONTROL-MIB::fanIdentification

OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-write

Description: String identifying each fan in a housing (e.g. CPU0, CPU1, PS0...)

What is fanIdentification?

Read-write string identifying a specific fan instance within a housing, e.g. 'CPU0', 'CPU1', 'PS0'. Lets an admin map an SNMP fan-fail alert directly to the physical unit to swap, since fanPositionX/Y/Z coordinates are obsolete.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17
snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::fanIdentification

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17.1
snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::fanIdentification.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17.1 s <value>

Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::fanIdentification OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
1.3.6.1.4.1.231.2.10sniExtensionsDESKTRAP-MIB
1.3.6.1.4.1.231.2.10.2sniServerMgmtFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2sniCommonFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2.5sniServerControlFSC-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.10.2.2.5.2environmentSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.2.2fansTableSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1fansSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.2.2.1.17fanIdentificationSNI-SERVER-CONTROL-MIB