SNI-SERVER-CONTROL-MIB :: cpuStatus

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SNI-SERVER-CONTROL-MIB › cpuStatus

cpuStatus

Module: SNI-SERVER-CONTROL-MIB

OID (symbolic): SNI-SERVER-CONTROL-MIB::cpuStatus

OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.6

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Status of a CPU: unknown(1) : CPU status could not be evaluated disabled(2) : CPU was manually disabled in BIOS setup ok(3) : CPU is available and operating properly not-present(4) : CPU is not available, empty socket error(5) : CPU has encountered errors but is still in use fail(6) : CPU has failed and is disabled missing-termination(7): CPU socket needs a terminator module when not populated but the terminator is missing prefailure-warning(8) : CPU has too many correctable errors within a certain time period

What is cpuStatus?

Read-only per-socket CPU health enumeration: ok(3), not-present(4) for an empty socket, error(5)/fail(6) for a faulting CPU, missing-termination(7) for a socket needing a terminator, or prefailure-warning(8) for excessive correctable errors. This is the primary value an operator alerts on to catch a CPU degrading before it fully fails.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.6
snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::cpuStatus

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.6.1
snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::cpuStatus.1

Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::cpuStatus OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
1.3.6.1.4.1.231.2.10sniExtensionsDESKTRAP-MIB
1.3.6.1.4.1.231.2.10.2sniServerMgmtFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2sniCommonFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2.5sniServerControlFSC-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.10.2.2.5.4systemBoardSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.4.1cpuTableSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1cpuSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.4.1.1.6cpuStatusSNI-SERVER-CONTROL-MIB