SNI-SERVER-CONTROL-MIB :: cabinetStatusDetail

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SNI-SERVER-CONTROL-MIB › cabinetStatusDetail

cabinetStatusDetail

Module: SNI-SERVER-CONTROL-MIB

OID (symbolic): SNI-SERVER-CONTROL-MIB::cabinetStatusDetail

OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.23

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: More detailed status information from this cabinet.

The StatusDetail object is set to reflect the new status. ok: (status ok) no failures detected. selftestWarning: (status degraded) the SCB firmware issued a warning condition. selftestFailure: (status error) the SCB firmware detected a failure that prevents it from functioning. powerFailure: (status degraded) the AC input at the power supply or the AC input at the UPS failed. fanFailure: (status error) A fan in this cabinet failed. The system is going to shut down. temperatureFailure: (status error) A sensor in this cabinet detected an over temperature. The system is going to shut down. communicationFailure: (status error) The SCB in the CPU cabinet has lost communication with the SCB in this cabinet. The system is going to shut down. powerOff: (status degraded) The cabinet is switched off.

What is cabinetStatusDetail?

Read-only bit-field giving the specific reason behind cabinetStatusSummary, e.g. fanFailure(16) or temperatureFailure(32) both indicating the system is heading toward a shutdown, or powerOff(128) simply meaning the cabinet is switched off. This is where an admin looks to find the actual root cause after cabinetStatusSummary flags a cabinet as degraded or in error.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.23
snmpwalk -v2c -c public <target> SNI-SERVER-CONTROL-MIB::cabinetStatusDetail

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.5.10.3.1.23.1
snmpget -v2c -c public <target> SNI-SERVER-CONTROL-MIB::cabinetStatusDetail.1

Start monitoring Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNI-SERVER-CONTROL-MIB::cabinetStatusDetail OID value, configure state conditions and alerts, and monitor any Siemens Nixdorf / Fujitsu Siemens / Fujitsu Technology Solutions server hardware, ServerView-managed (temperature/fan/CPU/memory hardware health) from a single console.

OID Breakdown

Upper-level ancestors (12 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
1.3.6.1.4.1.231.2.10sniExtensionsDESKTRAP-MIB
1.3.6.1.4.1.231.2.10.2sniServerMgmtFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2sniCommonFSC-SWITCH-MIB
1.3.6.1.4.1.231.2.10.2.2.5sniServerControlFSC-SWITCH-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.10.2.2.5.10systemControlInfoSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.10.3cabinetInfosTableSNI-SERVER-CONTROL-MIB
1.3.6.1.4.1.231.2.10.2.2.5.10.3.1cabinetInfosSNI-SERVER-CONTROL-MIB