SNA-SDLC-MIB :: sdlcPortStatsPhysicalFailures

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSNA-SDLC-MIBsdlcPortStatsPhysicalFailures

sdlcPortStatsPhysicalFailures

Module: SNA-SDLC-MIB

OID (symbolic): SNA-SDLC-MIB::sdlcPortStatsPhysicalFailures

OID (numeric): 1.3.6.1.2.1.41.1.1.3.1.1

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: This object reflects the total number of times this port has failed due to its physical media since port startup. At port startup time, this object must be initialized to zero.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.2.1.41.1.1.3.1.1
snmpwalk -v2c -c public <target> SNA-SDLC-MIB::sdlcPortStatsPhysicalFailures

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.2.1.41.1.1.3.1.1.1
snmpget -v2c -c public <target> SNA-SDLC-MIB::sdlcPortStatsPhysicalFailures.1

Start monitoring standards-compliant SNA/SDLC gateway equipment (SDLC port configuration/fault status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SNA-SDLC-MIB::sdlcPortStatsPhysicalFailures OID value, configure state conditions and alerts, and monitor any standards-compliant SNA/SDLC gateway equipment (SDLC port configuration/fault status) from a single console.

How to Use in IPNetwork Monitor

Select a standards-compliant SNA/SDLC gateway equipment (SDLC port configuration/fault status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type sdlcPortStatsPhysicalFailures into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. This object reflects the total number of times this port has failed due to its physical media since port startup. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases between polls, since a rising count of errors, failures, or discards often points to a real underlying problem. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.2mgmtAXON-MIB
1.3.6.1.2.1mib_2AXON-MIB
1.3.6.1.2.1.41snaDLCNETLINK-SPECIFIC-MIB
1.3.6.1.2.1.41.1sdlcNETLINK-SPECIFIC-MIB
Numeric OIDNameModule
1.3.6.1.2.1.41.1.1sdlcPortGroupSNA-SDLC-MIB
1.3.6.1.2.1.41.1.1.3sdlcPortStatsTableSNA-SDLC-MIB
1.3.6.1.2.1.41.1.1.3.1sdlcPortStatsEntrySNA-SDLC-MIB
1.3.6.1.2.1.41.1.1.3.1.1sdlcPortStatsPhysicalFailuresSNA-SDLC-MIB