SL81-STD-MIB :: trapEventTypeNumber

MIB Reference — IPNetwork Monitor · Updated September 23, 2026

All MIBs › SL81-STD-MIB › trapEventTypeNumber

trapEventTypeNumber

Module: SL81-STD-MIB

OID (symbolic): SL81-STD-MIB::trapEventTypeNumber

OID (numeric): 1.3.6.1.4.1.3052.5.3.4

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The user-defined trap variable for the type of event that happened. Here are the definitions: 1 Data Alarm 7 Serial Handshaking Low 8 Serial Handshaking High 10 Contact Closure Active 11 Contact Closure Inactive 12 Temperature High 13 Temperature Very High 14 Temperature Low 15 Temperature Very Low 16 Temperature Return to Normal 17 Humidity High 18 Humidity Very High 19 Humidity Low 20 Humidity Very Low 21 Humidity Return to Normal 26 Analog High 27 Analog Very High 28 Analog Low 29 Analog Very Low 30 Analog Normal 40 EventSensor Unresponsive 100 Contact Closure Active Reminder 101 Temperature High Reminder 102 Temperature High Very Reminder 103 Temperature Low Reminder 104 Temperature Very Low Reminder 105 Humidity High Reminder 106 Humidity Very High Reminder 107 Humidity Low Reminder 108 Humidity Very Low Reminder 109 Analog High Reminder 110 Analog Very High Reminder 111 Analog Low Reminder 112 Analog Very Low Reminder

What is trapEventTypeNumber?

A numeric code included in a trap identifying what kind of event triggered it - for example 12 for Temperature High, 17 for Humidity High, or 40 for an EventSensor going unresponsive - letting a trap receiver programmatically distinguish event types without parsing text.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3052.5.3.4
snmpwalk -v2c -c public <target> SL81-STD-MIB::trapEventTypeNumber

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3052.5.3.4.1
snmpget -v2c -c public <target> SL81-STD-MIB::trapEventTypeNumber.1

Start monitoring Asentria SL81-series remote site monitoring device (environmental sensor point/alarm status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SL81-STD-MIB::trapEventTypeNumber OID value, configure state conditions and alerts, and monitor any Asentria SL81-series remote site monitoring device (environmental sensor point/alarm status) from a single console.

OID Breakdown

Upper-level ancestors (7 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3052asentriaASENTRIA-ROOT-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3052.5sl81SL81-STD-MIB
1.3.6.1.4.1.3052.5.3productIdsSL81-STD-MIB
1.3.6.1.4.1.3052.5.3.4trapEventTypeNumberSL81-STD-MIB