SIEMENS-PN-MIB :: hicomSystemChanges

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SIEMENS-PN-MIB › hicomSystemChanges

hicomSystemChanges

Module: SIEMENS-PN-MIB

OID (symbolic): SIEMENS-PN-MIB::hicomSystemChanges

OID (numeric): 1.3.6.1.4.1.231.7.2.1.1.2

Node type: OBJECT-TYPE

Type: Counter32

Access: read-only

Description: When a change (SET) is made on hicomSysTable or hicomForeignSysTable, the variable is incremented by one.

What is hicomSystemChanges?

Counter that goes up by one each time a SET changes the Hicom system table or the foreign system table. A manager polls it and re-reads the tables only when the number has moved, instead of walking them constantly.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.7.2.1.1.2
snmpwalk -v2c -c public <target> SIEMENS-PN-MIB::hicomSystemChanges

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.7.2.1.1.2.1
snmpget -v2c -c public <target> SIEMENS-PN-MIB::hicomSystemChanges.1

Start monitoring Siemens Hicom 300 PBX, Siemens UNITY telephony system (topology/alarm/system-change status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SIEMENS-PN-MIB::hicomSystemChanges OID value, configure state conditions and alerts, and monitor any Siemens Hicom 300 PBX, Siemens UNITY telephony system (topology/alarm/system-change status) from a single console.

How to Use in IPNetwork Monitor

Select a Siemens Hicom 300 PBX, Siemens UNITY telephony system (topology/alarm/system-change status) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type hicomSystemChanges into the Find box to locate it in the OID tree, then select it and click OK. It reports the when a change (SET) is made on hicomSysTable or hicomForeignSysTable, the variable is incremented by one. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is a Counter32-type OID, Value bounds is the most useful condition here — trigger an alert if the counter increases sharply between polls relative to its normal baseline, since an unexpected spike often reflects a real change in traffic or activity. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.7siemensUnitsAN-MIB
1.3.6.1.4.1.231.7.2pnH150E-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.7.2.1hicomMibSIEMENS-PN-MIB
1.3.6.1.4.1.231.7.2.1.1hicomSystemSIEMENS-PN-MIB
1.3.6.1.4.1.231.7.2.1.1.2hicomSystemChangesSIEMENS-PN-MIB