SIAE-UNIT-MIB :: unitMissingAlarmSeverityCode

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SIAE-UNIT-MIB › unitMissingAlarmSeverityCode

unitMissingAlarmSeverityCode

Module: SIAE-UNIT-MIB

OID (symbolic): SIAE-UNIT-MIB::unitMissingAlarmSeverityCode

OID (numeric): 1.3.6.1.4.1.3373.1103.6.5

Node type: OBJECT-TYPE

Type: AlarmSeverityCode

Access: read-write

Description: Defines the severity associated to the unitMissingAlarm and enables/disables the trap generation on status change event.

What is unitMissingAlarmSeverityCode?

Configures the severity level assigned to unitMissingAlarm and whether trap generation is enabled for that alarm's state changes; defaults to majorTrapEnable. Adjust this if a missing-unit condition should be treated as more or less severe in your environment, or to silence its traps.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.3373.1103.6.5
snmpwalk -v2c -c public <target> SIAE-UNIT-MIB::unitMissingAlarmSeverityCode

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.3373.1103.6.5.1
snmpget -v2c -c public <target> SIAE-UNIT-MIB::unitMissingAlarmSeverityCode.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.3373.1103.6.5.1 s <value>

Start monitoring SIAE Microelettronica microwave radios with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SIAE-UNIT-MIB::unitMissingAlarmSeverityCode OID value, configure state conditions and alerts, and monitor any SIAE Microelettronica microwave radios from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.3373siaeMicroelettronicaSpaSIAE-TREE-MIB
1.3.6.1.4.1.3373.1103siaeMibSIAE-TREE-MIB
Numeric OIDNameModule
1.3.6.1.4.1.3373.1103.6unitSIAE-UNIT-MIB
1.3.6.1.4.1.3373.1103.6.5unitMissingAlarmSeverityCodeSIAE-UNIT-MIB