SERVERVIEW-DUPLEXDATAMANAGER-MIB :: fscDdmMpScDriverName

MIB Reference — IPNetwork Monitor · Updated September 14, 2026

All MIBsSERVERVIEW-DUPLEXDATAMANAGER-MIBfscDdmMpScDriverName

fscDdmMpScDriverName

Module: SERVERVIEW-DUPLEXDATAMANAGER-MIB

OID (symbolic): SERVERVIEW-DUPLEXDATAMANAGER-MIB::fscDdmMpScDriverName

OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.28

Node type: OBJECT-TYPE

Type: DisplayString

Access: read-only

Description: Name of the driver that handles the controller.

What is fscDdmMpScDriverName?

This reports the name of the OS driver managing the controller behind this MultiPath path. Admins check this when verifying whether all redundant paths to a disk are handled by the expected driver.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.28
snmpwalk -v2c -c public <target> SERVERVIEW-DUPLEXDATAMANAGER-MIB::fscDdmMpScDriverName

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.28.1
snmpget -v2c -c public <target> SERVERVIEW-DUPLEXDATAMANAGER-MIB::fscDdmMpScDriverName.1

Start monitoring Fujitsu PRIMERGY server, ServerView Agent (mirrored disk-write-cache duplex path status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SERVERVIEW-DUPLEXDATAMANAGER-MIB::fscDdmMpScDriverName OID value, configure state conditions and alerts, and monitor any Fujitsu PRIMERGY server, ServerView Agent (mirrored disk-write-cache duplex path status) from a single console.

OID Breakdown

Upper-level ancestors (8 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.231sniAN-MIB
1.3.6.1.4.1.231.2sniProductMibsApplication-Monitoring-MIB
Numeric OIDNameModule
1.3.6.1.4.1.231.2.10sniExtensionsSERVERVIEW-DUPLEXDATAMANAGER-MIB
1.3.6.1.4.1.231.2.10.2sniServerMgmtSERVERVIEW-DUPLEXDATAMANAGER-MIB
1.3.6.1.4.1.231.2.10.2.2sniCommonSERVERVIEW-DUPLEXDATAMANAGER-MIB
1.3.6.1.4.1.231.2.10.2.2.9fscDuplexDataManagerSERVERVIEW-DUPLEXDATAMANAGER-MIB
1.3.6.1.4.1.231.2.10.2.2.9.4fscDdmMPContainerSERVERVIEW-DUPLEXDATAMANAGER-MIB
1.3.6.1.4.1.231.2.10.2.2.9.4.1fscDdmMpPieceTableSERVERVIEW-DUPLEXDATAMANAGER-MIB
1.3.6.1.4.1.231.2.10.2.2.9.4.1.1fscDdmMpPieceSERVERVIEW-DUPLEXDATAMANAGER-MIB
1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.28fscDdmMpScDriverNameSERVERVIEW-DUPLEXDATAMANAGER-MIB