All MIBs › SERVERVIEW-DUPLEXDATAMANAGER-MIB › fscDdmMpMpCabinetHandling
fscDdmMpMpCabinetHandling
Module: SERVERVIEW-DUPLEXDATAMANAGER-MIB
OID (symbolic): SERVERVIEW-DUPLEXDATAMANAGER-MIB::fscDdmMpMpCabinetHandling
OID (numeric): 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.9
Node type: OBJECT-TYPE
Type: INTEGER
Access: read-only
Description: Connected storage type. If this cannot be detected the value is UNKNOWN. Possible values are: DEFAULT S40, JBOD CLARIION FibreCAT UNKNOWN none of the above
What is fscDdmMpMpCabinetHandling?
This reports which storage-array-specific handling profile this MultiPath group is using: default (for S40/JBOD arrays) or clariion (for FibreCAT arrays), or unknown if it couldn't be detected. Admins check this to confirm the driver is applying the correct failover behavior for their specific storage array model.
Examples
Walk all instances (SNMPv2c):
snmpwalk -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.9 snmpwalk -v2c -c public <target> SERVERVIEW-DUPLEXDATAMANAGER-MIB::fscDdmMpMpCabinetHandling
Get a specific instance (index 1):
snmpget -v2c -c public <target> 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.9.1 snmpget -v2c -c public <target> SERVERVIEW-DUPLEXDATAMANAGER-MIB::fscDdmMpMpCabinetHandling.1
Start monitoring Fujitsu PRIMERGY server, ServerView Agent (mirrored disk-write-cache duplex path status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SERVERVIEW-DUPLEXDATAMANAGER-MIB::fscDdmMpMpCabinetHandling OID value, configure state conditions and alerts, and monitor any Fujitsu PRIMERGY server, ServerView Agent (mirrored disk-write-cache duplex path status) from a single console.
OID Breakdown
Upper-level ancestors (8 from the standard OID tree / other modules)
| Numeric OID | Name | Module |
|---|---|---|
| 1 | iso | LANART-AGENT |
| 1.3 | org | AirPair-MIB |
| 1.3.6 | dod | AirPair-MIB |
| 1.3.6.1 | internet | AirPair-MIB |
| 1.3.6.1.4 | private | AirPair-MIB |
| 1.3.6.1.4.1 | enterprises | AirPair-MIB |
| 1.3.6.1.4.1.231 | sni | AN-MIB |
| 1.3.6.1.4.1.231.2 | sniProductMibs | Application-Monitoring-MIB |
| Numeric OID | Name | Module |
|---|---|---|
| 1.3.6.1.4.1.231.2.10 | sniExtensions | SERVERVIEW-DUPLEXDATAMANAGER-MIB |
| 1.3.6.1.4.1.231.2.10.2 | sniServerMgmt | SERVERVIEW-DUPLEXDATAMANAGER-MIB |
| 1.3.6.1.4.1.231.2.10.2.2 | sniCommon | SERVERVIEW-DUPLEXDATAMANAGER-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.9 | fscDuplexDataManager | SERVERVIEW-DUPLEXDATAMANAGER-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.9.4 | fscDdmMPContainer | SERVERVIEW-DUPLEXDATAMANAGER-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1 | fscDdmMpPieceTable | SERVERVIEW-DUPLEXDATAMANAGER-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1 | fscDdmMpPiece | SERVERVIEW-DUPLEXDATAMANAGER-MIB |
| 1.3.6.1.4.1.231.2.10.2.2.9.4.1.1.9 | fscDdmMpMpCabinetHandling | SERVERVIEW-DUPLEXDATAMANAGER-MIB |