SCTE-HMS-PS-MIB :: psInputVoltage

MIB Reference — IPNetwork Monitor · Updated October 02, 2026

All MIBs › SCTE-HMS-PS-MIB › psInputVoltage

psInputVoltage

Module: SCTE-HMS-PS-MIB

OID (symbolic): SCTE-HMS-PS-MIB::psInputVoltage

OID (numeric): 1.3.6.1.4.1.5591.1.4.2.1.23

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: Scaled representation of input 'line' or 'grid' voltage. This is an RMS value in 1/100 Volts units. This item requires an entry in the properties MIB.

What is psInputVoltage?

This is the power supply's analog input/line voltage reading, scaled in 1/100 Volt units; divide by 100 to get actual Volts. This only applies when psInputVoltageSupport reports analog(3) — for a binary(2) device, use psInputVoltagePresence instead.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5591.1.4.2.1.23
snmpwalk -v2c -c public <target> SCTE-HMS-PS-MIB::psInputVoltage

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5591.1.4.2.1.23.1
snmpget -v2c -c public <target> SCTE-HMS-PS-MIB::psInputVoltage.1

Start monitoring SCTE HMS-compliant cable-plant power supply units (capability/alarm/tamper status) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCTE-HMS-PS-MIB::psInputVoltage OID value, configure state conditions and alerts, and monitor any SCTE HMS-compliant cable-plant power supply units (capability/alarm/tamper status) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5591scteRootSCTE-ROOT
1.3.6.1.4.1.5591.1scteHmsTreeSCTE-ROOT
1.3.6.1.4.1.5591.1.4psIdentSCTE-HMS-ROOTS
Numeric OIDNameModule
1.3.6.1.4.1.5591.1.4.2psDeviceTableSCTE-HMS-PS-MIB
1.3.6.1.4.1.5591.1.4.2.1psDeviceEntrySCTE-HMS-PS-MIB
1.3.6.1.4.1.5591.1.4.2.1.23psInputVoltageSCTE-HMS-PS-MIB