discreteAlarmEnable

Module: SCTE-HMS-PROPERTY-MIB

OID (symbolic): SCTE-HMS-PROPERTY-MIB::discreteAlarmEnable

OID (numeric): 1.3.6.1.4.1.5591.1.1.3.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-write

Description: When set to enable(2 or 3), alarm processing for this property is enabled. When set to disable(1), alarm processing for this property is disabled. No entries into the alarmLogTable nor traps are permitted due to this property when in the disable(1) state. The default state for this object is disable(1). This object should be kept in NV memory

What is discreteAlarmEnable?

This read-write enumerated value, disable, enableMajor, or enableMinor, turns alarm processing for this discrete property entry on or off and sets its severity. When set to disable(1), the default state, no log entries or traps are generated for this discrete condition; setting it to enableMajor or enableMinor activates alarming, and the setting should be retained in NV memory. For example, setting discreteAlarmEnable to enableMajor on a tamper-switch entry ensures a trap and log entry are raised the moment the tamper condition is detected.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.3.1.3
snmpwalk -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::discreteAlarmEnable

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.3.1.3.1
snmpget -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::discreteAlarmEnable.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5591.1.1.3.1.3.1 i <value>

Start monitoring cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCTE-HMS-PROPERTY-MIB::discreteAlarmEnable OID value, configure state conditions and alerts, and monitor any cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5591scteRootSCTE-ROOT
1.3.6.1.4.1.5591.1scteHmsTreeSCTE-ROOT
1.3.6.1.4.1.5591.1.1propertyIdentSCTE-HMS-ROOTS
Numeric OIDNameModule
1.3.6.1.4.1.5591.1.1.3discretePropertyTableSCTE-HMS-PROPERTY-MIB
1.3.6.1.4.1.5591.1.1.3.1discretePropertyEntrySCTE-HMS-PROPERTY-MIB
1.3.6.1.4.1.5591.1.1.3.1.3discreteAlarmEnableSCTE-HMS-PROPERTY-MIB