SCTE-HMS-PROPERTY-MIB :: currentAlarmState

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SCTE-HMS-PROPERTY-MIB › currentAlarmState

currentAlarmState

Module: SCTE-HMS-PROPERTY-MIB

OID (symbolic): SCTE-HMS-PROPERTY-MIB::currentAlarmState

OID (numeric): 1.3.6.1.4.1.5591.1.1.1.1.3

Node type: OBJECT-TYPE

Type: INTEGER

Access: read-only

Description: The object contains the current alarm status associated with this property entry.

What is currentAlarmState?

This enumerated value, one of casNominal, casHIHI, casHI, casLO, or casLOLO, reports the alarm status currently in effect for this propertyTable row's monitored parameter. An admin polls this object to see at a glance whether a parameter such as a temperature or voltage reading is within normal range or has crossed one of its configured thresholds. For example, a reading of casHIHI(2) means the parameter's value has exceeded its analogAlarmHIHI threshold and a major alarm is currently active.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.1.1.3
snmpwalk -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::currentAlarmState

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.1.1.3.1
snmpget -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::currentAlarmState.1

Start monitoring cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCTE-HMS-PROPERTY-MIB::currentAlarmState OID value, configure state conditions and alerts, and monitor any cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) from a single console.

How to Use in IPNetwork Monitor

Select a cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) as the target host to create a monitor — the SNMP service should be up and running on it. Click New Monitor, then check SNMP Custom on the Favorites tab, click Next, and confirm the host. On the next page, click Select... to open the built-in SNMP MIB Browser and type currentAlarmState into the Find box to locate it in the OID tree, selecting the specific row/instance you want to monitor since this is a table column, then select it and click OK. The object contains the current alarm status associated with this property entry. On the monitor's Main parameters page you can set the target's SNMP port (default 161), credentials, polling interval, and other settings — see the SNMP Monitor help for details. On the State conditions and Alerting tabs, configure when the monitor should change state and trigger an alert; since this is an INTEGER-type OID, Value bounds is the most useful condition here — trigger an alert if the value is anything other than 'casNominal', since that indicates the condition this object reports has changed to one worth investigating. Click Finish to create the monitor; you can adjust any parameter later.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5591scteRootSCTE-ROOT
1.3.6.1.4.1.5591.1scteHmsTreeSCTE-ROOT
1.3.6.1.4.1.5591.1.1propertyIdentSCTE-HMS-ROOTS
Numeric OIDNameModule
1.3.6.1.4.1.5591.1.1.1propertyTableSCTE-HMS-PROPERTY-MIB
1.3.6.1.4.1.5591.1.1.1.1propertyEntrySCTE-HMS-PROPERTY-MIB
1.3.6.1.4.1.5591.1.1.1.1.3currentAlarmStateSCTE-HMS-PROPERTY-MIB