SCTE-HMS-PROPERTY-MIB :: analogAlarmLO

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SCTE-HMS-PROPERTY-MIB › analogAlarmLO

analogAlarmLO

Module: SCTE-HMS-PROPERTY-MIB

OID (symbolic): SCTE-HMS-PROPERTY-MIB::analogAlarmLO

OID (numeric): 1.3.6.1.4.1.5591.1.1.1.1.6

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The LO (Minor alarm) alarm occurs at this value. The unit associated with this property is the same as that of the parameter addressed. This object should be kept in NV memory.

Some devices only require 16 bit integer or smaller and therefore only support 16 bit (or smaller) values. Values outside of the supported range will return a bad value error.

What is analogAlarmLO?

This read-write Integer32 sets the threshold at which a LO, or minor, alarm is raised when the monitored analog parameter drops too low. An admin uses it to catch a value falling toward an unacceptable low range before it hits the more severe LOLO threshold, and the object should be stored in NV memory so it persists across reboots. For example, setting analogAlarmLO to 10 on an input-voltage row raises a minor alarm as soon as the voltage sags below 10.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.1.1.6
snmpwalk -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::analogAlarmLO

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.1.1.6.1
snmpget -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::analogAlarmLO.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5591.1.1.1.1.6.1 i <value>

Start monitoring cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCTE-HMS-PROPERTY-MIB::analogAlarmLO OID value, configure state conditions and alerts, and monitor any cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5591scteRootSCTE-ROOT
1.3.6.1.4.1.5591.1scteHmsTreeSCTE-ROOT
1.3.6.1.4.1.5591.1.1propertyIdentSCTE-HMS-ROOTS
Numeric OIDNameModule
1.3.6.1.4.1.5591.1.1.1propertyTableSCTE-HMS-PROPERTY-MIB
1.3.6.1.4.1.5591.1.1.1.1propertyEntrySCTE-HMS-PROPERTY-MIB
1.3.6.1.4.1.5591.1.1.1.1.6analogAlarmLOSCTE-HMS-PROPERTY-MIB