SCTE-HMS-PROPERTY-MIB :: analogAlarmHIHI

MIB Reference — IPNetwork Monitor · Updated October 06, 2026

All MIBs › SCTE-HMS-PROPERTY-MIB › analogAlarmHIHI

analogAlarmHIHI

Module: SCTE-HMS-PROPERTY-MIB

OID (symbolic): SCTE-HMS-PROPERTY-MIB::analogAlarmHIHI

OID (numeric): 1.3.6.1.4.1.5591.1.1.1.1.4

Node type: OBJECT-TYPE

Type: Integer32

Access: read-write

Description: The HIHI (Major alarm) alarm occurs at this value. The unit associated with this property is the same as that of the parameter addressed. This object should be kept in NV memory.

Some devices only require 16 bit integer or smaller and therefore only support 16 bit (or smaller) values. Values outside of the supported range will return a bad value error.

What is analogAlarmHIHI?

This read-write Integer32 holds the threshold value at which a HIHI, or major, alarm is raised for the analog parameter identified by this propertyTable row's parameterOID. An admin configures this in the same engineering units as the monitored parameter, and on some devices only a 16-bit range is actually supported, so out-of-range writes return a bad-value error. For example, setting analogAlarmHIHI to 100 on a temperature-monitoring row triggers a major alarm once the underlying sensor reads above 100 degrees.

Examples

Walk all instances (SNMPv2c):

snmpwalk -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.1.1.4
snmpwalk -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::analogAlarmHIHI

Get a specific instance (index 1):

snmpget -v2c -c public <target> 1.3.6.1.4.1.5591.1.1.1.1.4.1
snmpget -v2c -c public <target> SCTE-HMS-PROPERTY-MIB::analogAlarmHIHI.1

Set instance 1 (SNMPv2c):

snmpset -v2c -c private <target> 1.3.6.1.4.1.5591.1.1.1.1.4.1 i <value>

Start monitoring cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) with a free 30-day trial of IPNetwork Monitor. Create custom SNMP monitor using the SCTE-HMS-PROPERTY-MIB::analogAlarmHIHI OID value, configure state conditions and alerts, and monitor any cable/broadband HFC network element, transponder/line monitor/RF amplifier/fiber node/power supply (alarm-threshold property mechanism) from a single console.

OID Breakdown

Upper-level ancestors (9 from the standard OID tree / other modules)
Numeric OIDNameModule
1isoLANART-AGENT
1.3orgAirPair-MIB
1.3.6dodAirPair-MIB
1.3.6.1internetAirPair-MIB
1.3.6.1.4privateAirPair-MIB
1.3.6.1.4.1enterprisesAirPair-MIB
1.3.6.1.4.1.5591scteRootSCTE-ROOT
1.3.6.1.4.1.5591.1scteHmsTreeSCTE-ROOT
1.3.6.1.4.1.5591.1.1propertyIdentSCTE-HMS-ROOTS
Numeric OIDNameModule
1.3.6.1.4.1.5591.1.1.1propertyTableSCTE-HMS-PROPERTY-MIB
1.3.6.1.4.1.5591.1.1.1.1propertyEntrySCTE-HMS-PROPERTY-MIB
1.3.6.1.4.1.5591.1.1.1.1.4analogAlarmHIHISCTE-HMS-PROPERTY-MIB